9
2.3.1 CHANGING THE FLUE GAS CONNECTION
DIRECTION
Upon delivery, the stove is set up for rear flue gas connection provided no
other details are given. If the position of the flue gas connection is changed,
the following assembly steps must be performed:
Changing the flue gas connection direction from the rear to the top:
ambiente a1/a2/a3/a4/a4 H
2
O/RLU
Assembly from the rear to the top:
If the chimney connecting piece is
already assembled, this must be removed (Fig.
2a
point A). Remove the top
cover lid and the cover lid for the top flue gas connection (Fig.
2a
point B).
Undo the screws and remove the cover plate (Fig.
2b
point B and C). Then
disassemble the pipe nozzle of the rear outlet. Firstly remove the screws
(Fig.
2b
point D). Assemble the pipe nozzle on the top flue gas connection
(Fig. 2c point E and F). Then assemble the cover plate on the rear flue gas
connection (Fig.
2d
point E and F). Finally fit the cover lid for the rear flue
gas connection (chimney connecting piece) and reposition the cover lid (Fig.
2e
point E and G). Suitable storage stones can be fitted at the rear on the
ambiente a4 (see point 2.3.3. Assembly of the heat storage mass).
Assembly from the top to the rear:
If the chimney connecting piece is
already assembled, please remove (Fig.
2f
point A). Remove the top cover lid
and the cover lid for the rear flue gas connection (Fig.
2f
point B). Undo the
screws and remove the cover plate (Fig.
2g
point B and C). Then disassemble
the pipe nozzle of the top outlet. Firstly remove the screws (Fig.
2h
point C
and D). Assemble the pipe nozzle on the rear flue gas connection (Fig. 2i point
E). Then assemble the cover plate on the top flue gas connection (Fig.
2i
point
E and G). Finally fit the cover lid for the top flue gas connection (chimney
connecting piece) and reposition the cover lid (Fig.
2j
point E and G).
Dimension B
: Flue tube connection height with rear outlet
Dimension C:
Flue tube connection height when using the flue tube elbow set
Stove
Bore
dia. 150 mm
A
in mm
B
in mm
ambiente a1 / RLU
1025
1764
ambiente a2 / RLU
1025
1764
ambiente a3 / RLU
1145
1884
ambiente a4 / RLU
not possible
ambiente a4 H
2
O / RLU
1541
2257
ambiente a5
1124
1855
ambiente a6 heat accumulator
attachment
1306
2042
ambiente a6 convection air
attachment
1306
2042
amiente a6 H
2
O
1308
2048
ambiente a7
985
1756
ambiente a8
-
1756
B
A
Fig. 1b
Chapter 2