Electrical connection of pump control thermostat
B
Thermostat to control the pump (e.g. Afriso), with approx. 3.0 m connecting lead 2 x 0.75 mm²
C
Return flow temperature riser (circulating pump)
D
Terminal 1 not necessary!
E
Phase L (brown line)
F
Switched phase (L‘) blue lead
The functioning of the thermostatic switch can be checked before using it
for the first time with hot water (e.g., from a kettle) and a thermometer. Note
that the cover panel has to be removed in order to do this.
2.8.6 INTEGRATION IN A HEATING SYSTEM
Please note: The ambiente a4H
2
O/a6 H
2
O must only be installed in an
overall system after detailed planning of the overall heating system in
accordance with the relevant rules of technology and the safety stand-
ards. Proper configuration of the pumps, fittings, pipeline, buffer tank
and the safety components, is the responsibility of the planning firm
and/or of the company in charge of installation. For heating lines, we
recommend a minimum nominal copper pipe diameter of 22 x 1.0 mm,
or 3/4" for steel pipe. For cold water pipes a nominal pipe size (cop-
per pipe) of 15x1.0 and a flow pressure of 2.0 bar are sufficient for
safe operation. Possible variant for integration into a heating system.
A
Temperature sensor for thermal discharge safety device ½¨ internal thread
B
Temperature sensor for thermostatic switch ½¨ Internal thread
C
Return ¾¨ internal thread
D
Flow ¾¨ internal thread
Fig. 17b
The blue wire, the switched
phase (L') is wired as the phase
to the circulating pump or return
riser
The green/yellow wire is wired to
the earth wire (earth) (PE) of the
mains supply line.
The brown wire must be wired to
the phase (L) of the mains supply
line.