32
•
The LED must light up and air adjustment lever must move to the right.
• If the lever firstly moves to the left, swap over the white and red wires on the
control.
• The air adjustment lever must move to the right after max. 1 minute.
If not, swap the blue and brown wires on the control with each other and
repeat the self test
• Open the combustion chamber door, the air control lever must move to the
right.
• End of the self test. Now you can fire-up the oven. If no fire is started, approx.
10 minutes after closing the door, the air adjustment lever moves back to the
left to 0%.
3.3 FUNCTIONING OF THE ROTARY BASE
A rotary base can only be used with the ambiente a1/a2/a3/a4 models with top
flue gas connection and must be specified when ordering. The base enables the
stove to be rotated 180°, i.e. 90° to the left and 90° to the right (Fig. 20a).
A
Rotated 90° to the left
B
Normal position
C
Rotated 90° to the right
To rotate the stove, turn the lever adjustment bolt. This is located in the lower door
flap (see Fig.
20b
). After rotating the stove to the desired position, raise the lever
and turn it to the right to lock the stove in position (see Fig. 20b)
I
Raise the lever and turn it to the left
II
Rotate stove to desired position
III
Raise the lever and turn it to the right
IV
Rotate the stove until it locks into position
Fig. 20b I
Fig. 20b II
Fig. 20b III
Fig. 20b IV
Chapter 3
A
C
B
Fig. 20a
Exampl using a2