21
Stoves
Distance to side wall
Distance to rear wall
Distance in the area of radiant
heat of pane(s)
Dimensions of fire protection flooring
Distance for radiant
heat protection area
A
(cm)
B
(cm)
C
(cm)
D
(cm)
E
(cm)
combustible
not to be protected
combustible
not to be protected
combustible
not to be protected
length x width
Distance (with round flooring)
ambiente a1/RLU
15
10
10
5
80
80
50 x 30
50
66
ambiente a2/RLU
15
10
10
5
80
80
50 x 30
50
66
ambiente a3/RLU
15
10
10
5
80
80
50 x 30
50
66
ambiente a4/RLU
15
10
10
5
80
80
50 x 30
50
66
ambiente a4 H
2
O/RLU
10
10
5
5
80
80
50 x 30
50
66
ambiente a5
20
10
28
5
80
80
50 x 30
50
66
ambiente a6
15
10
10
5
80
80
50x30
50
88
ambiente a6 H
2
O
8
5
9
5
80
80
50x30
50
88
ambiente a7
15
10
15
5
70
70
50 x 30
50
100
ambiente a8
10
10
-
5
65
65
50 x 30
50
100
Chapter 2
Fig. 12
Flat glazing – (a5, a6, a6 H
2
0, a7, a8) all models cannot be rotated
Fig. 13
Curved glazing – (a1, a2, a3, a4, a4 H
2
0 cannot be rotated)
Brennbar
(z.B. Sessel)
D
C
A
B
Mittelpunkt
Brennraum
E
70°
Fig. 14
Curved glazing – (a1, a2, a3, a4 can be rotated)
Central point
Combustion
chamber
Combustible
(e.g.,
armchair)
Central
point
Combustion
chamber
Combustible
(e.g.,
armchair)
Central
point
Combustion
chamber
Combustible
(e.g.,
armchair)