TH-G Series Brushless Dc Motor Driver User’s Manual Version 3.3 Jan,2016
TH-G Series Brushless Dc Motor Driver User’s Manual Version 3.3 Jan,2016
4,2
**** **
Hall sensor error
1. incorrect or loose wiring or a
damaged Hall sensor.
2. Also be caused by incorrect hall
angle configuration (60 degree or
120 degree).
4,3
**** ***
Motor over-
temperature
Motor temperature has exceeded the
configured maximum. the Controller
will Shut Down until the motor
temperature.
4,4
**** ****
Motor locked rotor
When in locked rotor condition, the
max output phase current of the
motor will be limited to 90% of
previous current. once this problem
disappears, the fault will clear and
the max output phase current will
return to normal
The Red LED flashes once at power on as a confidence check and then
normal stays Off. "1, 2" means the Red flashes once and after a second
pause, flashes twice. The pause time between multiple flash code groups is
two seconds.
Contacts us:
SPARK MOTORS PVT. LTD.
Website: www.sparkmotors.in
E-mail: [email protected] / [email protected]
Tel: (022-27781125)