Page 2: ...ged before the motor is switched on Mode of operation and extent of electronic power assistance As soon as you switch on the electric assistance system and begin pedaling electronic power assistance is available The necessary pedal power reduces in proportion to each increase in the level of assistance see p 6 Selection of assistance level by approximately 60 50 or 30 Changing the level of electro...

Page 3: ...e it from the bicycle Attention For reasons of safety you should make sure that you have removed the key Charging process 1 Plug the charging device into a 220 volt socket Grasp the battery and insert it into the slot provided for it on the charging station 2 The LEDs of the battery light up When all 5 LEDs are glowing red the battery is fully charged 3 Remove the battery from the charging station...

Page 4: ...elow 0 C or above 40 C the charger will remain in the standby mode and the battery cannot be charged Before starting to ride Check the remaining capacity of the battery to determine whether it is sufficient for riding to your destination If the button on the display panel marked Push is pressed this will show the remaining capacity of the battery This is an approximate value In very cold weather a...

Page 5: ... programme After this the battery status indicators light up and show the remaining capacity of the battery If the lower power LED is blinking you must charge the battery immediately before use see section on LED light mode when riding Battery status indicator LED All three LEDs on means about 70 100 capacity remains Two LEDs on about 40 70 One LED is on about 10 20 LED blinks slowly blinks quickl...

Page 6: ...lowly The battery charge has dropped to a low level The remaining battery power is 9 of capacity Recharging is recommended Blinking rapidly and goes out after about 3 minutes The battery is completely dead A recharge is necessary immediately Other forms of LED status are explained in the chapter Self diagnosis The LED can show when an excessively high drain of energy is being consumed on a constan...

Page 7: ... For stopping Neither the gearshift nor the mode switch should be activated First activate the rear wheel brake or front wheel brake and rear wheel brake simultaneously Stop Press the on off switch to interrupt the current flow Care and maintenance information on the battery Have the electric drive system checked regularly by your dealer Do not perform any repair operations on the electric drive s...

Page 8: ...nger than two weeks the sleep mode returns Also the battery self discharges over time and it will enter the sleep mode after a down time of approx 4 months even if it is fully charged The battery must be fully charged at least every six months otherwise irreparable damage may occur Batteries cannot be disposed of with regular domestic waste Do not charge your bicycle battery in any other charger C...

Page 9: ...er The delivery includes the type NKJ38 charger Before use take the charger out of the cardboard box and remove the plastic wrapping If you do not do this the outside of the charger can be deformed by the heat Store the charger in a dry place if you are not charging the battery Inexpert handling can cause serious accidents or injuries Never bring the contacts of the charger together during the cha...

Page 10: ...ns The charger should only be set up in a secure stable position on a suitable surface Do not cover the charger or place objects on it risk of overheating or fire Self diagnosis The control unit of the control panel has a self diagnosis mode With the aid of self diagnosis any improper function of the electrical system can be determined The error code is identified by different modes of blinking nu...

Page 11: ...otor unit defective Overload One mode diode no blinking when cooled Reduce support degree by two steps Strong overload One mode diode no blinking when cooled Reduce support degree by 1 step Transmission error Last power diode and further Reduce support degree by 2 steps Reset Press Off and On twice to reset Position error of the torque sensor To avoid this error do not use the pedals for the first...

Page 12: ...oes not come on 3 motor defect or drive problem battery LED does not come on 3 contact your dealer 1 have the battery tested at your dealer s support not given 1 Indicator error control switch 1 See self diagnosis of the control switch 2 Malfunction of control switch 2 check whether the cover foil of the control switch is damaged If so contact your dealer 2 automatic switch off activated 2 check w...

Page 13: ... have the battery terminal voltage checked 5 incomplete charge due to abnormal termination of charging process 5 please repeat charging process Battery charge status indicator 1 ageing end of service life of battery 1 Check the useful life of the battery Replace the electrical components on your bicycle only with parts tested for the corresponding model We wish you a lot of pleasure when using you...

Page 14: ...6 V 10 Ah 260 Wh 8 Ah weight 2 2 kg 10 Ah weight 2 4 kg Service life 3 4 years 500 charging cycles Charger Charging time approx 3 hours first charge at least 4 h Weight of charger 530 g Current supply 220 V 50 Hz alternating current Power 62 W range distanc e up to 80 km in the case of average use optimal conditions and fully charged battery This bicycle satisfies the requirements of the following...