Form 43343050
-2-
Jan 2014
1.0)
SAFETY
This heater is a self-contained infrared radiant tube heater designed for use in poultry applications. Safety
information required during installation and operation of this heater is provided in this manual and the labels on
the product. The installation, service and maintenance of this heater must be performed by a contractor
qualified in the installation and service of gas fired heating equipment.
All personnel in contact with the heater must read and understand all safety information, instructions and labels
before operation. The following symbols will be used in this manual to indicate important safety information.
Warning
Warning
Warning
Warning instructions must be followed to prevent or avoid hazards which
may cause serious injury, property damage or death.
Caution
Caution
Caution
Caution instructions must be followed to prevent incorrect operation or
installation of the heater which may cause minor injury or property
damage.
2.0)
INSTALLER RESPONSIBILITY
The installer is responsible for the following:
••••
The heater and venting, as well as electrical and gas supplies must be installed in accordance with these
installation instructions and any applicable codes and regulations.
••••
Every heater shall be located with respect to building construction and other equipment so as to permit
access to the heater.
••••
Each installer must follow the clearances to combustible materials for the heaters.
••••
Install the heater so that the supports and hangers are correctly spaced in accordance with these
instructions. The heater must be supported by materials having a working load limit of at least 115lbs.
••••
Supply the owner with a copy of these Installation and Operation Instructions.
••••
Where unvented heaters are used, gravity or mechanical means shall be provided to supply and exhaust at
least 4 CFM per 1,000 Btu/hr input of installed heaters.
••••
Never use the heater as a support for a ladder or other access equipment. Do not hang anything from the
heater.
••••
Supply all installation materials necessary that are not included with the heater.
••••
Check the nameplate to make sure that the burner is correct for the gas type in the building and the
installation altitude.
3.0)
GENERAL INFORMATION
This heater is a self-contained infrared radiant tube heater designed for use in poultry houses where flammable
gases or vapors are not generally present.
For indoor installation only. Not for us
For indoor installation only. Not for us
For indoor installation only. Not for us
For indoor installation only. Not for use in residential dwellings.
e in residential dwellings.
e in residential dwellings.
e in residential dwellings.
INSTALLTION REQUIREMENTS:
INSTALLTION REQUIREMENTS:
INSTALLTION REQUIREMENTS:
INSTALLTION REQUIREMENTS:
Installation of this heater must be in accordance with all applicable codes shown in the instructions and/or the
local codes and authorities having jurisdiction. In the absence of local codes, the heater must be installed in
accordance to the National Fuel Gas Code ANSI Z223.1/NFPA54 in the U.S. or the Natural Gas and Propane
Installation Code CSA B149.1 in Canada. Heaters shall be installed by a licensed contractor or licensed installer.
Clearances to combustibles as outlined in the manual should always be observed. In areas used for storage of
combustible materials where they may be stacked below the heater, NFPA54 requires that the installer must
post signs that will “specify the maximum permissible stacking height to maintain the required clearances from
the heater to combustibles.”
Inspect all openings regularly and clean as necessary. This is necessary because litter, dust feathers and other
matter can become airborne and clog openings and adversely affect heater operation and performance.
Every heater shall be located with respect to building construction and other equipment so as to permit access
to the control housing. Each installer shall use skillful and reliable installation practices when locating the
heaters and must give consideration to service accessibility.