Split Inverter Air-to-Water Heat Pump
Control
Touch Screen Wire Controller Interface Introduction - Key and Icon Function Instruction
Key Function Instruction
Hero series DC inverter heat pump
- 4 -
I. Touch screen wire controller interface introduction
Celsius symbol
Timer icon
Cooling
Heating
Automatic
Wifi signal
Mode key
Down
Auxiliary
interface
Up
On/off key
Main
interface
Mute key
Defrosting
Clock key
2.Key and icon function instruction
2.1 Key function instruction
Key symbols
Designation
Function
Mute key
Under the heating mode or heating mode under the automatic mode,
the mute key operation is effective and used to enter and exit the mute
mode with one click.
Mode key
It is used to switch the unit mode, temperature setting, and parameter
setting.
It is also used to "save" when commissioning a unit.
On-off key
It
is
used
to
turn on or turn off
,
cancel
current
operation,and
return
to
the
last
level
of
operation.
Up key
It is used to page up, and increase variable value.
Down key
It is used to page down, and decrease variable value.
Clock key
It is used as user clock, and to carry out timing setting.
Fahrenheit symbol
Second symbol
Minute symbol
Hour symbol
Pressure symbol
Flow symbol
Celsius symbol
Fahrenheit symbol
Compressor symbol
Inlet symbol
Pump symbol
Parameter setting symbol
Fan symbol
Outlet symbol
Timer mute symbol
Lock symbol
Timer symbol
Time interface
Error symbol
Hero series DC inverter heat pump
- 5 -
Icon symbol
Designation
Function
Cooling symbol
Display when unit is cooling. When in remote mode and no call for
heating or cooling, cooling symbol will be displayed.
Heating symbol
Will display when unit is in heating
.
Defrosting symbol
Display while the unit is in defrost mode.
Compressor symbol
Display when the compressor is running
.
Water pump symbol
It
will
display
when
when the circulation pump is running
.
Fan symbol
It
will
display
when
the fans are running.
Mute symbol
When
the
timing
mute
function
is
started,
it
keeps
bright
for
a
long
time.
When
it
is
in
mute
state,
it
will
flash.
Or
else,
it
is
off.
Timing symbol
It will display after the user sets the timing, and multiple timing intervals
can be set .
Locking key symbol
When
the
keyboard
is
locked,
it
is
on.
Fault symbol
Will display upon any faults (see faults section)
.
Degrees
Celsius
symbol
When
main
display
area
or
auxiliary
display
area
displays
degrees
Celsius,
it
is
on.
Degrees Fahrenheit
symbol
When main display area or auxiliary display area displays degrees
Fahrenheit, it is on.
Setting symbol
When the parameter is adjustable, it is on
Second symbol
When main display area displays second digit, it is on.
Minute symbol
When main display area displays minute digit, it is on.
Hour symbol
When main display area displays hour digit, it is on.
12
Operation Instructions
3
LoadDisplay
Lock screen
Defrost
Compressor Fan Water Pump Electric Heating Four-way Valve
BasicFunctions
z1
ON/OFF
Long press for 3s to power on Long press for another 3s to power off
2
Mode
Long press “M” for
3s to switch to
Cooling
and
Heating
Temp
eratur
e
adjust
ment
Cooling temperature adjustment range: 41-77
O
F
Press “Up” arrow to increase the water temperature;
press “Down” arrow to decrease the water temperature;
press “Mode” to save the settings and press “ON/OFF”
to return to the main interface. If there is no operation
for 10 seconds, it will not save the settings and return to
the main interface.
Heating temperature adjustment range: 77-130
O
F
Mode