60
Operating manual Soyer Bolzenschweißtechnik
12.1.3 Setting/deactivating the SRM current
If you do not have specified values, the table in chapter
“12.1.1 Help tables for device
” on page 58 can be used as an aid for a basic setting.
If an SRM current value > 0 A is set, SRM is automatically activated during welding
with the set current value. If the setting is 0 A, SRM is deactivated.
Setting/deactivating the SRM current
Step 1:
Connect the device as described in chapter
welding device and the stud welding guns
Step 2:
Use the
↑↓ arrow keys to select the
position for the SRM current setting.
The LED lights up if the selection is
correct.
Step 3:
Use the +/- keys to set the required
value for the SRM current on the
display.
The SRM current is adjustable from
0 - 1500 mA (display in A) in 50 mA
steps (0.05 A).
If the setting is "0", SRM is deactivated.
The SRM current has been set.