Step 8:
Slide the stud chuck to the end stop in
the spring piston of the gun.
Step 9:
Hand-tighten the union nut.
Step 10:
Insert a stud and check the stud
protrusion.
The stud/stud flange must protrude
1 - 1.5 mm out of the shielding gas cap.
If necessary, correct the setting of the
stud chuck by shifting the tripod.
Step 11:
Tighten the four socket head screws.
Assembly is complete.