Operating manual Soyer Bolzenschweißtechnik
25
6.3.1
Display and setting area
Figure 3: Display and setting area
Item
Designation
a
Function selection
The following functions can be selected using the arrow keys:
• Welding current
• Welding time
• SRM current (deactivated at value 0 A, activated at value > 0 A)
• Gas preflow time (deactivated at value 0 s, activated at value > 0 s)
• Lift test (see chapter “12.1.5 Setting the lift time (height of lift) in the "Setup"
mode
The LED next to the selected function lights up.
b
+/- keys
For setting the value of the selected function shown on the display.
c
Display
The set values of the selected function are shown on the display.
d
Display of the operating state
The following operating states are displayed during welding operation:
• Trigger button of the gun is pressed
• Gun is placed on the workpiece and ready for welding
• SRM is active
• Gas preflow is active
The LED next to the active operating state lights up.
+
SRM
GAS
]
A
[
]
ms
[
]
A
[
]
s
[
]
ms
[
GAS
SRM
>
a
b
d
c
Summary of Contents for BMK-10i