background image

 

 

Page III 

The Quality Name in High Voltage Switching 

 

 

LIMITED WARRANTY 

 

Southern States, LLC (“SSLLC”) warrants only to the Warranty Holder (hereinafter defined as the “End User” or 

the “Immediate Purchaser”, as applicable, pursuant to the terms and conditions of this Limited Warranty as set 

forth below), that the Product identified below will, upon shipment, be free of defects in workmanship and material 

for the applicable Warranty Period. The “Warranty Period” is that period of time during which this Limited 

Warranty is effective, and such period begins on the invoice date issued by SSLLC for the Product, and continues 

until the earlier to occur of (1) the expiration of the Warranty Duration period, or (2) the Number of Operations, 

both as specified in the table below. If the Product is both purchased and installed within the United States or 

Canada, this Limited Warranty is granted to each end user of the Product who acquired the Product for its own 

use during the Warranty Period (“End User”). In all other situations, this Limited Warranty is granted only to the 

first purchaser of the Product (“Immediate Purchaser”) from SSLLC. No primary or remote purchaser or owner 

of the Product who is not a Warranty Holder may claim any benefit under this Limited Warranty, or any remedial 

promise included in this Limited Warranty. SSLLC shall, upon prompt written notice from the Warranty Holder, 

correct a nonconforming Product by repair or replacement at the sole discretion of SSLLC of the nonconforming 

Product or any part or component of a nonconforming Product necessary in SSLLC’s discretion to make such 

Product conforming. Any transportation charges, labor for removing, reinstalling the Product or part, and/or costs 

related to providing access to the Product shall be the responsibility of the Warranty Holder. Correction in this 

manner will  constitute the Warranty Holder’s exclusive remedy and fulfillment of all SSLLC’s liabilities and 

responsibilities hereunder. SSLLC’s duty to perform under this limited warranty may be delayed, at SSLLC’s 

sole option, until SSLLC has been paid in full for all products purchased by the Warranty Holder. No such delay 

will extend the Warranty Period. If SSLLC does not make such repair or replacement, SSLLC’s liability for 

damages on account of any claimed nonconformity will in no event exceed the purchase price of the Product in 

question. This Limited Warranty does not apply to any Product that has been disassembled, repaired, or altered 

by anyone other than SSLLC. This Limited Warranty will not apply to any Product that has been subjected to 

improper or abnormal use of the Product. SSLLC has no responsibility to repair or replace any Product or 

component thereof manufactured by another party, but SSLLC will assign, to the extent assignable, to the 

Warranty Holder any manufacturers’ warranty that applies to products and components not manufactured by 

SSLLC.   

 

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES. THERE 

ARE NO OTHER EXPRESS, IMPLIED, OR STATUTORY WARRANTIES. ALL IMPLIED 

WARRANTIES WHICH MAY ARISE BY IMPLICATION OF LAW, OR APPLICATION OF COURSE 

OF DEALING OR USAGE OF TRADE, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES 

OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, NONINFRINGEMENT OR 

OTHERWISE ARE EXPRESSLY EXCLUDED. SSLLC SHALL NOT BE LIABLE OR RESPONSIBLE 

FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT, EXEMPLARY, SPECIAL, OR PUNITIVE 

DAMAGES, EVEN IF SSLLC HAS BEEN ADVISED OF THE POSSIBILITY OF SAME. THE 

WARRANTY HOLDER IS SOLELY RESPONSIBLE FOR THE SUITABILITY OF THE PRODUCT 

FOR ANY PARTICULAR APPLICATION.   

Product Purchased 

Region 

Product Installed 

Region 

Warranty Holder 

Warranty Duration 

U.S and Canada 

U.S and Canada 

End User 

Five (5) Years 

All Other Conditions 

Immediate 

Purchaser 

Earlier of 1 year from 

installation or 18 months 

from shipment 

 

 

Summary of Contents for COLE L

Page 1: ...COLE TYPE L Copper Center Break Disconnect Switch For 8 3 72 5 kV Ratings INSTRUCTION INSTALLATION MANUAL...

Page 2: ...Page I The Quality Name in High Voltage Switching...

Page 3: ...Page II The Quality Name in High Voltage Switching Safety Information...

Page 4: ...his manner will constitute the Warranty Holder s exclusive remedy and fulfillment of all SSLLC s liabilities and responsibilities hereunder SSLLC s duty to perform under this limited warranty may be d...

Page 5: ...Page IV The Quality Name in High Voltage Switching Southern States LLC Equipment Receipt Installation Use Operation and Maintenance Terms Terms of Use...

Page 6: ...Page V The Quality Name in High Voltage Switching...

Page 7: ...Page VI The Quality Name in High Voltage Switching Type L 8 3 72 5 kV...

Page 8: ...al Disconnect Switch 4 Receiving Handling Storage 5 Unpacking 5 Storage 5 Installation Adjustment Procedures 6 Recommended Tools Values 6 Preferred Switch Assembly Method 7 Operating Mechanism 9 Final...

Page 9: ...mmended Installation and Maintenance Table 16 Figures Page Figure 1 Type L 69kV 1600 amp 4 Figure 2 Insulator Attachment 7 Figure 3 Mounting Live Parts 7 Figure 4 Blade Clearance A B 8 Figure 5 Typica...

Page 10: ...ire obligations of Southern States The Warranty contained in the contract between the parties is the sole warranty of Southern States Any statements contained herein do not create new warranties or mo...

Page 11: ...uthern States LLC in the event conditions associated with a specific application are not sufficiently addressed All photographs and sketches in this manual are for illustration purposes only and may n...

Page 12: ...ting kV 8 3 15 5 27 38 48 3 72 5 BIL kV 95 110 150 200 250 350 ADDITIONAL RATINGS Rated Power Frequency 60 Hz Continuous Current 1200A 2000A Short Time Symmetrical Withstand 3 Sec 38 kA RMS 50 kA RMS...

Page 13: ...g the insulators F to the switch base A Mounting the live parts B to the insulators Mounting the switch base A to the structure Installing operating mechanism components Final adjustment or tuning A S...

Page 14: ...ontact the factory Storage All components of the Cole Type L center break disconnect switch are suitable for outdoor use Keep bearings out of standing water Keep upright and support live parts with ba...

Page 15: ...rocedures Recommended Tools Values Table 2 Recommended Tools and Torque Values Recommended Tools Recommended Torque Values Type Sizes Bolt Nut size Torque Ft lb Hand Wrenches and or Sockets 15 16 3 4...

Page 16: ...ference Exception Vertically mounted switches should always be assembled on the ground When assembling the switches on the ground so not attempt to make contact adjustments until the switch is mounted...

Page 17: ...ds 7 Check the main pivot bolt on the live part hinge to make sure it is tight 8 Manually test operate checking for proper contact engagement The blade should enter the jaw centrally with equal cleara...

Page 18: ...ure 5 Figure 5 Typical Operating Arrangement 3 Caution The pipe collar above the vertical bearing must support the entire weight of the vertical operating pipe To prevent unnecessary component damage...

Page 19: ...inue tuning the other two phases one at a time 2 Switch Operating Devices 2 1 Worm gear operator HOGO High Output Geared Operator Optional 2 1 1 The operator handle is factory set to rotate clockwise...

Page 20: ...7 Type SEGO Safety Enhanced Gear Operator 3 3 Electrical motor operator 3 3 1 Please refer to motor operator instruction manual for proper installation and setup 3 3 2 Use manual operation while comp...

Page 21: ...If the switch is fully open before the operator reaches the fully open position the adjustable arm radius is too long Close the switch match mark the adjustable arm and the pipe clevis and loosen the...

Page 22: ...Refer to Table 2 5 9 2 Apply a minimal amount of grease to the point of each piercing bolt and then tighten the bolt until it pierces the pipe wall For heavy walled pipe schedule 80 or above 3 or abov...

Page 23: ...gonally from its original location This is the best option as it allows for the original setup to be maintained 1 3 2 Maintain the operator on the same side of the structure Assemble the components us...

Page 24: ...and mounting bracket as a complete assembly 5 1 2 If the insulators have not been installed unbolt the live parts from the switch bearings and flip the paddle arms on each bearing along the long axis...

Page 25: ...es on the switches which can be eliminated during normal switch maintenance Table 3 Recommended Installation and Maintenance Table Installation Tests Patrolling Inspection 6 months Routine 5 Year Peri...

Page 26: ...se during any operation or maintenance cycle as exposed surfaces such as contacts are vulnerable to environmental conditions and contaminants that can decrease the effectiveness of the grease over tim...

Page 27: ......

Page 28: ...orgia Avenue Hampton Georgia 30228 Phone 770 946 4562 Fax 770 946 8106 E mail support southernstatesllc com http www southernstatesllc com 2021 Southern States LLC IB 107 Cole L Rev6 02182021 Printed...