PRE JUDGE:
OFF
TURNMODE
OFF
LOCK
ARC MODE:
DATA
NO JUDGE
OFF
OFST
CH CHECK
OFF
RMT
ERR
SAVE
F1
F2
F3
F4
F5
4.2.3.3 SYSTEM3
Instruction:
Label
Instruction Definition
PRE JUDGE OFF
OFF: do not distinguish between the primary and
secondary test.
1-50
Final step number of the primary test: once the step
number is selected, the primary tests ends in this step.
*In this test, no fail result displays when the
primary test ends, subsequent tests will be
stopped.
TURNMODE OFF
OFF: when all the items in the present files are tested,
the test is finished.
ON
Loop test: after the end of the test, it will retest from
scratch automatically.
*Set the stop condition or press “STOP” key to
stop testing.
ARC MODE DATA
Data mode: take ARC current data as reference.
LEVL
Level mode: take ARC level as reference.
NO JUDGE
OFF, ON
When judging PASS / FAIL, take the opposite result.
CH CHECK
OFF, ON
This function is valid only for ST9201S/SX. When the
function is ON, four test terminal pairs 1-2, 3-4, 5-6
and 7-8 will be formed by default. In each test, the
instrument will first check whether the selected pair of
two test lines is shorted and then test the product in
accordance with the set requirements.
INTERFACE
INTERFACE
GPIB ADD:
03
DATA:
8
LOCK
BAUD:
19200
PARITY:
NONE
OFST
STOP:
2
RMT
ERR
SAVE
F1
F2
F3
F4
F5
4.2.3.4 INTERFACE