background image

Service Record Mio Carbon (Design 2018)

1 of 28

2020-09-01

Mio Carbon

Mio Carbon

   

   

Design 2018

Design 2018

Unique people, unique solutions.

Service Record Mio Carbon (Design 2018)

ENG

Service Record

Service Record

In the following all individual adjustments of the wheelchair are 

described.

 These adjustments require tools and specialised 

knowledge. Please leave the adjustments to a qualified rehab 

consultant.  

Summary of Contents for Mio Carbon

Page 1: ...18 Unique people unique solutions Service Record Mio Carbon Design 2018 ENG Service Record Service Record In the following all individual adjustments of the wheelchair are described These adjustments...

Page 2: ...anges and misprints reserved The pictures in this Instructions for use can differ from the actual equipment components How ever a corresponding conduction is possible Copyright All texts pictures and...

Page 3: ...3 3 Assembly group back 14 3 3 1 Adjust back height 14 3 3 2 Adjust back angle 14 3 4 Assembly group leg support 15 3 4 1 Standard leg support 15 3 5 Assembly group side guards 16 3 5 1 Adjust the sid...

Page 4: ...020 09 01 1 Wheelchair overview 1 back cushion 2 brake lever 3 seat molding 4 frame 5 caster fork 6 caster 7 foot plate 8 rear wheel 9 hand rim 10 back 11 stabiliser bar 12 skirt guard 13 rear wheel 1...

Page 5: ...ntation indications Please note Information about before sale can be found in the instructions for use Infomation for the user can be found in the instructions for use For maintenance instructions see...

Page 6: ...Setting or adjusting the angle open close Turn clockwise Turn counter clockwise steps to be done at the same time steps to be done after each other steps to be done on both sides Use A B 1 1 1 2 2x 2...

Page 7: ...y nuts must be replaced by new ones Only the regular maintenance of all safety relevant parts on the wheelchair by a qualified rehab workshop protects against damage and maintains our manufacturer s w...

Page 8: ...support angle 3 1 2 Camber The camber and toe adjustment settings can be found in the separate service booklet Camber and toe compensation This can be found at http www sorgrollstuhltechnik de 3 1 3...

Page 9: ...ps up to 4 5 cm and gives the following seat heights in the front Distance top edge of the seat to Distance top edge of the seat to ground without seat cushion ground without seat cushion degree of de...

Page 10: ...mpletely 3 remove the firm curved back plate from the connection angles to the side panels remove the side panels completely t 3 2 3 Seat supporting angle 2 Leave the seat supporting angle C connected...

Page 11: ...ning the spacer bus hing must sit on the outside between the side holder and side guard Then mount the seat plate in the new position 2 Mount the seat plate in the internal holes B of the seat support...

Page 12: ...at it stands at the rear approx 20 30 mm 2 3 cm beyond the firm curved back plate 2 seat supporting angle mounted at the very front 3 Backrest mounted at the back In this state the seat depth can be c...

Page 13: ...ecisive factor for the optimal grip point and thus a positive force balance Especially with young users the acceptance of the aid and thus the success of the rehabilitation measure are decided For thi...

Page 14: ...to the bevel of the back plate to the outside the shoulder blades can still be moved freely To change the position of the firm curved back plate 1 2 completely remove screws A on both sides put firm c...

Page 15: ...nstall screws A and tighten Horizontal adjustment of the leg support ang le adjustment of the footplate holder 2 loosen screws A on both sides Place the footplate holder B on both sides in the same de...

Page 16: ...ection 1 The clothes guard A can be adjusted in height loosen all screws B on both sides Move clothes guard A tighten all screws B again 2 if necessary the length of the brake lever C must be adapted...

Page 17: ...et snow mud ice dirt etc crazy profile worn brake pin loosened brake bolt bolts dirty drum brake defective Bowden cable with drum attendant or one hand brake too much distance between brake pressure p...

Page 18: ...UZS release 2 For changing the distance between the brake pressure pin and the rear wheel If necessary loosen both screws C on both sides with the brake open move the entire brake body to the new posi...

Page 19: ...n the screw tightly The lowest hole F is due to the design and must not be used The anti tipper bar could slip out of the holder when turning activating the anti tipper 3 If the wheelchair is set very...

Page 20: ...sen both screws B move the locking joint A and retighten the screws B Vertical setting 2 On the other hand the truss pads can be adjusted by turning the c bar D Remove the locking joint A by unscrewin...

Page 21: ...er replace the covers Horizontal extension 3 For the horizontal extension add an exten sion piece spare part Remove the screw A add the extension piece and screw it together on both ends 2 A A B 1 3 A...

Page 22: ...tighten the screws A firmly The holes are spaced 20 mm apart The front part B of the outdoor front end must always be fixed in the telescopic tube D with both screws A Mount the outdoor front end Clos...

Page 23: ...components regularly with a mild household water based cleaner and then dry it thoroughly In addition clean the rear wheels and the casters and free the axles of dirt and impurities e g hair etc Wash...

Page 24: ...nsity of use and the number of re uses is 5 years For this purpose the product must be used within the intended purpose and intended use the instructions in the instructions for use must be followed a...

Page 25: ...nal check of all mechanical adjusting devices carried out Checklist maintenance and care user A poor or neglected maintenance of the wheelchair represents a significant safety risk Before each use Ple...

Page 26: ...of wheelchair min SW 310 mm max SW 365 mm absolute length of wheelchair with 18 605 mm without push handles with 20 630 mm with 22 695 mm with 24 745 mm absolute height of wheelchair min 500 mm withou...

Page 27: ...018 a class 1 device is and it complies with the EG Directive 93 42 EWG Annex VII on medical devices This was confimred by a conformity assessment procedure according to the me dical Pruoduct Guidelin...

Page 28: ...chnik GmbH Co KG Benzstra e 3 5 68794 Oberhausen Rheinhausen Germany Fon 49 7254 9279 0 Fax 49 7254 9279 10 info sorgrollstuhltechnik de www sorgrollstuhltechnik de company stamp Service Record Mio Ca...

Reviews: