![Sony XDCAM PDW-510 Operation Manual Download Page 26](http://html.mh-extra.com/html/sony/xdcam-pdw-510/xdcam-pdw-510_operation-manual_417490026.webp)
C
h
apt
er 2
L
o
c
a
tions
and
F
u
n
c
tion
s
of
P
a
rt
s
and
Con
tr
o
ls
26
2-3 Audio Functions
j
AUDIO SELECT CH-1/CH-2 (audio channel-1
and channel-2 adjustment method selection)
switches
These switches select the audio level adjustment method
for each of audio channels 1 and 2.
AUTO:
Select this setting for automatic adjustment.
MANUAL:
Select this setting for manual adjustment.
k
AUDIO IN CH-1/CH-2 / CH-3/CH-4 (audio input
selection) switches
AUDIO IN CH-1/CH-2 switches
These switches select the audio input signals to be
recorded on audio channels 1 and 2.
FRONT:
The input signal source is the microphone
connected to the MIC IN connector.
REAR:
The input signal source is the audio equipment
connected to the AUDIO IN CH1/CH2 connectors.
WIRELESS:
The input signal source is a WRR-855A/
855B UHF Synthesized Tuner Unit (option).
AUDIO IN CH-3/CH-4 switches
These switches select the audio input signals to be
recorded on audio channels 3 and 4.
F (front):
The input signal source is the microphone
connected to the MIC IN connector.
R (rear):
The input signal source is the audio equipment
connected to the AUDIO IN CH1/CH2 connectors.
W (wireless):
The input signal source is a WRR-855A/
855B UHF Synthesized Tuner Unit.
With a CA-701 Camera Adaptor (option) connected to the
camcorder, you can record separate sounds on audio
channels 3 and 4.
l
LINE /AES/EBU / MIC selectors
These select the audio source of the audio input signals
input to the AUDIO IN CH1/CH2 connectors.
LINE:
Line input audio equipment
AES/EBU:
AES/EBU format audio signal
MIC:
Microphone input
Note
When these switches are in the MIC position, and the
+48V switch described below is on, if you inadvertently
connect any audio device other than a microphone to the
AUDIO IN CH1/CH2 connectors, the device may be
damaged.
m
+48V/OFF switches
Select either of the following positions for the
microphones to be connected.
+48V:
For a microphone to use an external power supply
OFF:
For a microphone to use an internal power supply
n
AUDIO OUT (audio output) connector (XLR type,
5-pin, male)
This connector outputs the audio signals recorded on audio
channels 1 and 2 or audio channels 3 and 4.
The MONITOR CH-1/2 / CH-3/4 switches allow you to
select the audio signal to be monitored.
o
AUDIO IN CH1/CH2 (audio channel-1 and
channel-2 input) connectors (XLR type, 3-pin,
female)
These are audio input connectors for channels 1 and 2 to
which you can connect audio equipment or a microphone.
When the LINE / AES/EBU / MIC selector is set to AES/
EBU, the CH1 connector is used for channel-1 and -2
inputs, and the CH2 connector, for channel-3 and -4 inputs.
p
DC OUT 12 V (DC power output) connector (4-pin,
female)
This connector supplies power for a WRR-862 UHF
Portable Tuner (option). Do not connect any equipment
other than the UHF portable tuner.
Summary of Contents for XDCAM PDW-510
Page 8: ...8 ...
Page 12: ...12 Table of Contents ...
Page 20: ...Chapter 1 Overview 20 1 5 MPEG 4 Visual Patent Portfolio License ...
Page 86: ...Chapter 4 Scene Selection 86 4 4 Using the PDZ 1 Proxy Browsing Software ...
Page 116: ...Chapter 6 File Operations 116 6 4 Recording Continuous Time Code With FAM and FTP Connections ...
Page 174: ...Chapter 9 Setting Up the Camcorder 174 9 9 Connecting the Remote Control Unit ...
Page 220: ...Index 220 Index ...