35
Frame counter
Reads out the number of frames output.
The counter can be reset.
Timing Chart
Trigger latency/Exposure time
The values of trigger latency (time from the trigger acceptance to the exposure start) are as follows.
XCG-CG160/CG160C
XCG-CG510/CG510C
* Setting on overlap trigger prohibited. Variation in trigger latency and exposure time varies depending on output mode
settings.
XCG-CG240/CG240C
* Setting on overlap trigger prohibited. Variation in trigger latency and exposure time varies depending on output mode
settings.
Register
FrameCounter
FrameCounterReset
Register
Parameter
Trigger latency
Exposure time
FastTriggerMode
On (0)
approx. 0.2 µs
ExposureTime ± (approx. 0 µs to approx. 13 µs)
Off (1)
approx. 11 µs to approx. 107 µs
(XCG-CG160/CG160C)
ExposureTime ± (approx. 0 µs to approx. 36 µs)
(XCG-CG160/CG160C)
approx. 41 µs to approx. 184 µs
(XCG-CG510/CG510C)
ExposureTime ± (approx. 0 µs to approx. 62 µs)
(XCG-CG510/CG510C)
Trigger latency
Exposure time
approx. 40 µs to approx. 140 µs
ExposureTime ± (approx. 0 µs to approx. 47 µs)
Trigger signal
Exposure
Sensor output
Trigger latency
Exposure time