20
Image flip (Same level as
output format)
Flips an image vertically and horizontally.
Reboot the unit to reflect the changes of the setting.
Gain
Manual gain
The manual gain can be finely set in 0.1 dB.
Although the settable lower/upper limit values of the
gain are slightly different in each camera, the gain
parameter value can be set from –1 dB or less to 27 dB
or more. Same as the gain, the parameter value of the
GainAnalogRaw can be set from –10 or less to 270 or
more. The setting rage of the gain that guarantees image
quality is from 0 dB to 18 dB.
Auto gain (AGC)
By setting AUTOGAIN, the gain is automatically
adjusted according to the image pickup environment.
AGC works so that the average level in a detection frame
may reach AGC-LEVEL. The AGC detection frame is
set to the central region by default. The detection frame
can be displayed or the detection area changed.
Register
Parameter
Function
ReverseX/
ReverseY
0
Off (no flip)
1
Flip vertically
2
Flip horizontally
3
Rotation of 180
degrees
Register
Parameter
Setting
Gain
–1 or less ~ 0 ~ 27 or
more
Gain dB unit
GainAnalogRaw –10 or less ~ 0 ~ 270 or
more
Gain advanced
setting
Register
Parameter
Setting
GainAutoMode Off (0)
Manual gain
Once (1)
One-push AGC
Continuous (2)
Continuous AGC
GainAutoLevel
0 to 11264 to 16383 AGC target level
(14 bits)
GainAuto-
Speed
1 to 192 to 256
AGC convergence
speed
GainAuto-
UpperLimit
–10 or less ~ 180 ~
270 or more
AGC upper limit
GainAuto-
LowerLimit
–10 or less ~ 0 ~
270 or more
AGC lower limit
DetectArea-
GainAuto
Off (0)
AGC detection frame is
hidden
On (1)
AGC detection frame is
displayed
DetectArea-
GainAutoWidth
0 to 50 to 100
Width size of AGC
detection frame
DetectAreaWB-
AutoHeight
0 to 50 to 100
Height size of AGC
detection frame
DetectAreaWB-
AutoOffsetX
0 to 25 to 100
Horizontal position of
AGC detection frame
DetectAreaWB-
AutoOffsetY
0 to 25 to 100
Vertical position of
AGC detection frame
OffsetX
OffsetY
Height
Width
Detection frame area
Whole screen