42
GPO output system diagram (example of GPO1)
Sensor Readout (Sensor Output)
This signal indicates that exposure has completed and the image sensor has entered the video output sequence (enabled
only when operating the trigger mode). Output is available from the GPO2/3 terminals. The sensor readout signal is
asserted before optical black (OB) and the effective pixel area is output. Image might not be output properly, if trigger
signal is input while this signal is asserted.
Pulse Train Generator
Pulse waveforms can be output from the GPO2/3 connector. Available range is 0.5Hz to 100kHz.
Register
Parameter
PWMPulseDutyT
1 to 2000000 [µs]
PWMPulseCycleT
10 to 2000000 [µs]
0
1
0
1
Trigger signal
Exposure
Sensor output
Trigger through signal
Exposure signal
Sensor readout signal
Pulse signal
Strobe control signal
(GPO1)
User definition 1
User definition 2
User definition 3
LineSource
LineInverter
GPO2
GPO3
StrobeActiveDelay
StrobeActiveTime
Trigger signal
Exposure signal
Sensor readout signal
(Sensor output)
Trigger latency