26
Latency and pulse width from the specified time can be set. Specifying the pulse width to 0 maintains the condition.
When the pulse width is set to 0, the signal flips over each time you execute the command. Please keep in mind that if
the next command time comes earlier than the set pulse width, the signal flips over.
When the pulse width is a value other than 0
When the pulse width is a value 0
Special trigger
When operating in trigger mode and performing image pickup in different conditions (such as the shutter, gain, and
image pickup area), the setting has to be changed in advance for each trigger input. However, if the special trigger
operation is enabled, the setting does not have to be changed and continuous image pick up in different conditions is
facilitated. Up to 16 settings can be configured. There are the bulk operations in which images are taken consecutively
by inputting the trigger signal once and the sequential operation in which images are taken each time the trigger signal
is detected. The next exposure is started after the end of video output. In the sequential operation, the second and
subsequent trigger signals should be input 5 ms or more after the end of video output. The special trigger operation and
trigger mode operation cannot be enabled at the same time. The source and polarity of the special trigger signal should
be defined separately from the trigger mode. Each setting should be saved in the user set. For the items reflected, refer
to “Command List” (page 47).
* XCG-CG160/CG160C: Unavailable. Dedicated to output.
Register
Parameter
Setting
ActionCommandPulseDelayLine2
Latency time
Line2 latency time
ActionCommandPulseWidthLine2
Pulse width
Line2 pulse width
ActionCommandPulseDelayLine3
Latency time
Line3 latency time
ActionCommandPulseWidthLine3
Pulse width
Line3 pulse time
Register
Parameter
Setting
SpecialTriggerMode
Off (0)
Special trigger off
Bulk (1)
Bulk trigger
Sequential (2)
Sequential trigger
Register
Parameter
Setting
SpecialTriggerSource
Line1 (0)
DC IN connector 2nd pin
Line2 (1)
DC IN connector 3rd pin*
Line3 (2)
DC IN connector 4th pin*
Software (4)
Software command
Register
Parameter
Setting
SpecialTriggerActivation
FallingEdge (0)
Negative
RisingEdge (1)
Positive
NumberOfMemoryForSpecialTriggerMode
1 to 2 to 16
Number of shot images during the bulk operation
Latency
Designated time
Designated time
Pulse width
Pulse width
Latency
Latency
Latency
Designated time
Designated time