Functions
Partial Scan
Only the area selected from the effective pixel area can
be read out. Adding 2 pixels of vertical and horizontal
directions achieves higher sensitivity and frame rate.
The area size is selected by the Height and Width
registers, and the read beginning point is selected by the
OffsetX and OffsetY registers. Reducing Height
increases the frame rate, but changing the Width register
does not change the frame rate. Partial scan can be set
with or without a trigger.
OffsetX and OffsetY relate to Width and Height as
follows:
O Width
≤
Width (maximum value)
O Height
≤
Height (maximum value)
Note
Since the shutter setting has priority, use a shutter speed
high enough to enable partial scan at a higher frame rate.
Configurable range
Configurable values
The values of OFFSETX, OFFSETY, WIDTH and
HEIGHT increase or decrease in steps of 4.
Binning (XCG-CG160
only)
Adding 2 pixels in the vertical and horizontal directions
achieves higher sensitivity and frame rate.
Note
To fasten the frame rate on binning, use the shutter in a
sufficiently high speed.
Width
Height
XCG-CG160/
CG160C
16 to 1440 to 1456 16 to 1080 to 1088
XCG-CG240/
CG240C
16 to 1920 to 1936 16 to 1200 to 1216
XCG-CG510/
CG510C
16 to 2448 to 2464 16 to 2048 to 2056
Register
Parameter
Setting
BinningVertical
1
Vertical binning is not
available
2
Vertical binning is available
BinningHorizontal
1
Horizontal binning is not
available
2
Horizontal binning is
available