Page 2: ...he State of California USA only Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate Perchlorate Material Lithium battery contains perchlorate For the customers in Europe for CCU 790P This product with the CE marking complies with both the EMC Directive and the Low Voltage Directive issued by the Commission of the European Community Compliance with these d...

Page 3: ... 11 Settings of the camera 11 Status display of the camera system 11 Self diagnostics of the camera system 11 Settings of the network 12 Self diagnostics results of the CCU 790 790P internal boards 13 Self diagnostics results of the camera internal boards 14 ROM version indication 15 Exiting the Self diagnostic mode 15 When an error occurs 15 Specifications 15 General 15 Input signals 15 Output si...

Page 4: ...era equipped with the AC OUT connector is connected to the CCU 790 790P the video camera can supply power which is supplied from the CCU 790 790P to an external device through the AC OUT connector This can be done by the setting on the video camera For details refer to the Operation Manual supplied with the video camera 10 MHz wideband triax transmission Wideband triax transmission with Y signal a...

Page 5: ... a headset f CAMERA POWER switch and indicator This switch controls the power supply to the video camera when the MAIN POWER switch is set to the ON side I position The indicator lights when power is supplied to the video camera If an RCP 750 751 920 921 Remote Control Panel is connected to this unit the CAM PW switch on the panel must be lit for control of the power supply to the camera with this...

Page 6: ...ctors The REFERENCE INPUT connectors RET 1 connectors and the RET 2 PROMPTER connectors are loop through connectors A REFERENCE INPUT connectors BNC type The upper connector accepts reference signals black burst signal for external synchronization The input signal is output from the lower connector The reference input signal can be terminated at 75 ohms internally To terminate the signal input the...

Page 7: ...tails consult your Sony service personnel F SPARE connector BNC type Not used d OUTPUT connectors A VBS composite video signal SDI serial digital interface 1 VBS SDI 2 VBS SDI 3 connectors BNC type Supply the signal from the video camera in composite or SDI format Use the switch on the internal board to select the composite video signal or SDI signal For details on the internal boards consult your...

Page 8: ...t might have excessive voltage to this port Follow the instructions for this port g INTERCOM TALLY PGM program audio connector D sub 25 pin Inputs outputs intercom tally or program audio signals Connects to an intercom tally or program audio connector of an intercom system h MIC REMOTE microphone remote control connector D sub 15 pin Connects to an external control unit such as an audio mixer With...

Page 9: ...input through the INCOM TALLY PGM connector PROD Producer line PRIV Producer line and engineer line are cut off and communication is possible only between the CCU 790 790P and the camera connected to the rear panel of the CCU 790 790P ENG Engineer line The settings regarding the output intercom signals can be performed on the internal AU board For details consult your Sony service personnel c Head...

Page 10: ... never be connected to or disconnected from the CCU 790 790P when the power is turned on Always turn the unit off first Video camera Some switches or controls on the video camera may not work when the camera is connected to the CCU 790 790P For details refer to Operation Manuals of the video camera and the camera adaptor The maximum power output from the CAMERA connector of the CCU 790 790P is 360...

Page 11: ...e ROM version indication page appears a screen with no characters character OFF screen appears When you keep pressing the CHARACTER button pages are automatically turned to the character OFF screen In this manual self diagnostics pages are shown in order of appearance The following illustrations of the self diagnostics pages may differ from the actual indications depending on the settings and conn...

Page 12: ...mission status of the REMOTE connector RCP CNU Power Power supply status of the REMOTE connector Page 3 Intercom CCU CCU intercom selection Intercom CAMERA CH1 Status of intercom 1 of the camera producer line engineer line Intercom CAMERA CH2 Status of intercom 2 of the camera producer line engineer line CHU MIC Gain Gain and control status of the microphone circuit Settings of the network The fol...

Page 13: ... CCU 790 790P internal boards For details on the internal boards refer to the System Manual DM board CAM Video Status of the Y R Y and B Y signals of the triax signal Skin Gate Reception status of the Skin gate signal from the camera TRIAX Comp Cable compensation of a triax cable TRIAX Step Compensation step of the triax cable step indication in the circuit The cable length may not be displayed co...

Page 14: ...mber of the AU board IV board RETURN Input settings for the return channels 1 to 4 MIX Y Setting for camera signal to be mixed with the return signal Power IV board power supply status DIF Power status of the DIF board connected to the rear of the IV board PLD Status of the PLD mounted on the IV board and program version of the PLD BoardID ID number of the IV board EN board Component Setting statu...

Page 15: ... ON current probe method 90 A 240 V 2 Hot switching inrush current measured in accordance with European standard EN55103 1 20 A 230 V Cable length1 50 to 1 000 m Fujikura φ8 5 mm 75 to 1 500 m BELDEN 9232 φ13 2 mm 100 to 2 000 m Fujikura φ14 5 mm Operating temperature 5 C to 40 C 41 F to 104 F Storage temperature 20 C to 50 C 4 F to 122 F Dimensions 424 133 394 mm 163 4 51 4 155 8 in w h d not inc...

Page 16: ...or 6 R G B and Y R Y B Y are switchable Camera input output signals CAMERA Triax Kings type for the U S A and Canada Fischer type for Europe COAX BNC type 1 75 ohms REMOTE 8 pin multiconnector ETHERNET IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX INTERCOM TALLY PGM D sub 25 pin 1 4W RTS TALLY 24 V DC TTL level or contact selectable MIC REMOTE D sub 15 pin 1 INCOM on the front panel XLR 5 pin 1 Suppl...

Page 17: ... equipment described in this manual Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation Trademark Ethernet is a registered trademark of Xerox Corporation ...