3-18 (E)
HDC-P1
A
3-4-3. Crispening Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI 1 and SDI 2 connectors
Object: Grayscale
chart
Preparations
.
Setting for MSU-900
DETAIL OFF button
→
ON (dark)
.
Shoot the grayscale chart so that the chart frame is
aligned with the underscanned monitor frame.
.
Iris of the lens: A = 600
?
20 mV
Adjustment Procedure
1. Perform the automatic white balance adjustment.
WHITE
button/MSU-900
→
ON (lit)
2. Adjust the crispening level.
MSU menu operation:
.
PAINT button
→
ON (lit)
.
Touch panel operation
(Page 1/4)
→
[Detail]
→
[Detail|1]
Adjustment item:
Crispening
Speci
fi
cation:
Set crispening to
_
99 once, and
then increase it slowly to set it to
the point where the noise in the
black-level area of the waveform
starts decreasing or set to a proper
crispening level.