3-9 (E)
PMW-EX1R
Item8 to 11: Diagnosis between display and media blocks
Diagnosis between display and media blocks analyzes the following contents.
Item No.
ID
Diagnosis description
Error value
Type 1/2 Note
8
0x90
Video signal line communication
-1: Test pattern checking failure
1, 2
_
test in recording direction (in the
-2: Sequence error
direction from base band processing
IC to AVIT signal processing IC)
9
0x91
Video signal line communication
-1: Test pattern checking failure
1, 2
_
test in playback direction (in the
-2: Sequence error
direction from AVIT signal processing
IC to base band processing IC)
10
0x92
LPCM signal line communication
-1: Test pattern checking failure
1, 2
_
test in recording direction (in the
-2: Sequence error
direction from base band processing
IC to AVIT signal processing IC)
11
0x93
LPCM signal line communication
-1: Test pattern checking failure
1, 2
_
test in playback direction (in the
-2: Sequence error
direction from AVIT signal processing
IC to base band processing IC)
.
When an error is detected, it indicates a possible failure in the chip or the signal line between chips.
n
Do not execute item12, 13.
3-4. Executing Log Dump
Executing Log Dump acquires the error log information and saves it to the active, writable media.
Select Log Dump under the INFORMATION menu, and execute it with Execute. The process is complete
when “Log Dump Done” is displayed as a result.
n
Do not remove the media until Log Dump message appears.