Pre
par
at
ion
Connecting the Unit
8
Preparation
The Preparation section explains what the administrator
has to prepare for monitoring images after connection of
the unit.
Connecting the Unit
Controllable cameras
The SNT-V704 enables control of the following video
cameras or cameras using the following protocols.
x
Cameras manufactured by Sony
BRC-300 series
EVI-D100 series
EVI-D70 series
SSC-DC590/DC690 series
x
Cameras and camera protocols not manufactured by
Sony
Pelco-D (Spectra III)
Bosch Dome Control Code Protocol (Bi-phase)
BBV RS422 Telemetry Control Protocol (RS-485
StarCard)
American Dynamics RS-422 Protocol
GE Digiplex Protocol
Honeywell VCL Protocol
Each camera needs each setting. For details, see “Setting
the Camera” on page 31.
Connecting BRC-300, EVI-D100 and EVI-
D70 series
Up to four cameras can be connected to SNT-V704 at
the same time.
1
Connect the
t
connector 1 to 4 of SNT-V704 and
the video output connector of each camera.
When connecting cameras, connect from the
t
connector 1 to 4 in order. If these are connected at
random, this unit may not work properly.
2
Connect VISCA RS-232C connectors of SNT-
V704 and each camera.
Refer also to the Instruction manuals of the camera
for connection of the camera.
Note
1
12
13
24
RS-232C
I/O
SEE INSTRUCTION MANUAL
CLASS 2 WIRING DC 12V
1
2
3
4
SNT-V704 (rear)
VISCA cable
(not supplied)
BRC-300 series (rear)
BRC-300 series (rear)
BRC-300 series (rear)
BRC-300 series (rear)
VI
SCA
c
a
b
le
(not
supplied)
VISCA cable
(not supplied)
VISCA cable
(not supplied)
75-ohm coaxial
cable (not supplied)