65
Troubleshooting
Chap
ter
5
Mis
c
e
llan
eou
s
Wiring Diagram for Audio Output
Wiring Diagram for Sensor Input
Wiring Diagram for Relay Output
Troubleshooting
Before contacting your retailer or a Sony Support Center,
please check the following items. If the problem persists,
contact them.
The NSR does not work.
• Verify that the power cable is connected correctly.
• Make sure the wall outlet has power. Test it by plugging
another device.
The monitor remains blank.
• Verify whether the power cord is correctly connected.
• Verify whether the monitor cable is correctly connected.
Confirm that the monitor is connected to monitor
connector.
The new external hardware is not working
properly.
• Make sure the cables for the new external device are
firmly connected and the pins are not bent.
An external device connected to a USB connector
does not work.
• This unit supports standard USB 2.0 Mass Storage
devices. Depending on the type of USB 2.0 Mass
Storage device, however, errors may occur when writing
data to the device. If errors occur when writing data, use
a USB flash memory device of a different type.
• To ensure proper operation of USB devices, do not
connect the devices via a USB hub. Connect the devices
directly to the USB connectors on the unit. Operation is
not guaranteed when devices are connected via a USB
hub, USB switch, or extension cable.
• Refer to the documentation that came with the USB
device.
The NETWORK LED does not light up.
• Check the cabling and network equipment for the proper
connection.
Cannot access the hard disk drive.
• Due to rapid flashing during frequent access to the hard
disk drive, the HDD LED may appear to be steadily lit.
The NSR heats up quickly
• When one unit is stacked on top of another unit, the heat
generated by both units can get extremely hot. Do not
stack units on top of each other, place the unit on other
objects that may generate heat, or install the unit in
confined spaces.
47 k
Ω
Inside of this unit
Outside
Example) Headphone
Audio
Codec
220
μ
F
RL=16
Ω
/32
Ω
Vcc = 5 V
Sensor In 1, 2, 3, 4
200
Ω
Inside of this unit
Outside
Sensor In 1G, 2G, 3G, 4G
(Example)
Relay
30 V DC
125 V AC
1 A or less
Inside of this unit
Outside
Vcc
Relay Out +
Relay Out –
(Example)