6-78
HVR-V1J/V1U/V1N/V1E/V1P/V1C
6.
Contrast Adjustment (OO-003 board)
Set the video signal level for driving the LCD to the specified
value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
Mode
CAMERA
Subject
Not required
Measurement Point
Pin
5
of CN1014 (EVF_VG) on
TT-003 board
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
3C, 77
Specified Value
A = 2.30
±
0.05 Vp-p
Note:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
71
01
Press PAUSE (Write) button.
3
C
77
Change the data and set the
voltage (A) to the specified
value. (The data should be
“00” to “7F”.)
4
C
77
Press PAUSE (Write) button.
5
C
77
Read the data and this data is
named D
77
.
6
C
3C
D
77
Press PAUSE (Write) button.
7
3
70
10
Press PAUSE (Write) button.
8
3
70
Check the data changes to
“11”.
9
0
01
00
A: Between the pedestal and 3 steps peak
Fig. 6-1-29
3 steps peak
Pedestal
A
2H
7.
White Balance Adjustment (OO-003 board)
Correct the white balance.
If deviated, the EVF screen color cannot be reproduced.
Mode
CAMERA
Subject
Not required
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
3A, 3B
Specified Value
EVF screen must not be colored
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Check the white balance only when replacing the fol-
lowing parts. If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC6601
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
71
01
Press PAUSE (Write) button.
3
C
3A
80
Press PAUSE (Write) button.
4
C
3B
80
Press PAUSE (Write) button.
5
Check that the EVF screen is
not colored. If not colored,
proceed to step 6.
6
C
3A
Change the data so that the
3B
EVF screen is not colored.
(Note 3)
7
3
70
10
Press PAUSE (Write) button.
8
3
70
Check the data changes to
“11”.
9
0
01
00
Note 3:
To write in the non-volatile memory (EEPROM), press
the PAUSE (Write) button each time to set the data.
The data of page: C, address: 3A should be “66” to “B2”.
The data of page: C, address: 3B should be “60” to “A6”.