6-73
HVR-V1J/V1U/V1N/V1E/V1P/V1C
47. Color Reproduction Check (Outdoor SD: ND 2)
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Color bar chart (Color reproduction
adjustment frame)
Filter
ND filter 1.0, 0.4 and 0.1
Measurement Point
Video terminal of
Adjusting remote
A/V jack
commander
(75
Ω
terminated)
Measuring Instrument
Vectorscope
Specified Value
All color
Data of page: 6,
luminance
address: 0C is
points should
“00”
settle within each
color
reproduction
frame.
Note 1:
Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ......................................... DV
Checking method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
0
01
01
3
0
10
0A
4
E
8C
01
Press PAUSE (Write) button.
(AE)
5
0
10
00
6
6
C9
10
7
6
CA
04
8
6
D0
47
*9
0
10
06
(*PAL model only)
*10
D
5E
(*PAL model only)
(6D)
Note down the data.
*11
D
5E
5C
(*PAL model only)
(6D)
Press PAUSE (Write) button.
*12
0
10
00
(*PAL model only)
13
6
01
3D
Press PAUSE (Write) button.
14
6
02
Check the data changes to
“01”.
15
6
0C
Check the data is “00”.
16
Adjust the GAIN and
PHASE of the vectorscope,
and set to the burst lumi-
nance point to the burst
position of color reproduc-
tion frame.
17
Check that the each color
luminance point is in each
color reproduction frame.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
CA
00
3
6
C9
00
4
0
10
0A
5
E
8C
00
Press PAUSE (Write) button.
(AE)
*6
0
10
06
(*PAL model only)
(*PAL model only)
*7
D
5E
Set data noted down at step
(6D)
10, and press PAUSE (Write)
button.
8
0
10
00
9
0
01
00
10
Remove the C14 filter on the
lens.