6-46
HVR-V1J/V1U/V1N/V1E/V1P/V1C
14. F No. & ND Light Quality Standard Data Input
RadarW
RadarW
RadarW
Correct the lens iris and dispersion of the ND filter light quantity.
Subject
Clear chart (Center frame)
Adjustment Page
6D
Adjustment Address
60 to 6F
Note 1:
Perform “LV Standard Data Input” after this adjustment.
Note 2:
If reading/writing data on pages 6D, set data: 06 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 6D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) FOCUS ................................................................... MANUAL
4) ZOOM .................................................................... WIDE end
5) REC FORMAT (Menu setting) ............................. HDV1080i
6) STEADY SHOT (Menu setting) ..................................... OFF
7) D. EXTENDER (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Center Frame”. If not,
Perform “13. Picture Frame
Setting (Center Frame)”
2
0
01
01
3
6
17
10
4
6
C9
10
5
6
10
80
6
6
D2
60
7
6
D3
40
8
6
01
BB
Press PAUSE button. (Note
4)
9
6
02
Check the data changes to
“01”.
10
6
0C
Check the data is “00”.
Note 4:
The adjustment data will be automatically input to page:
6D, address: 60 to 6F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
17
00
2
6
C9
00
3
6
10
00
4
6
01
00
Press PAUSE button.
5
0
01
00
13. Picture Frame Setting (Center frame)
Subject
Clear chart (Center frame)
40 cm (PTB-1450) from the front of
lens)
Measurement Point
Video terminal of A/V jack (75
Ω
terminated)
Measuring Instrument
Monitor TV
Specified Value
A clear chart must be shot in larger
size than nine grids in the center of
frame shown on the screen.
(Fig. 6-1-17)
Switch setting
1) POWER ......................................................... CAMERA mode
2) FOCUS ................................................................... MANUAL
3) ZOOM .................................................................... WIDE end
4) D. EXTENDER (Menu setting) ...................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
Setting method:
Order Page Address Data
Procedure
1
Shoot a clear chart in the
center of screen with the
zoom at WIDE end.
2
0
01
01
3
0
10
09
4
F
4A
08
Press PAUSE (Write) button.
(9F)
5
F
4B
81
Press PAUSE (Write) button.
(9F)
6
Check that a clear chart is
shot in larger size than nine
grids in the center of frame
shown on the screen.
7
F
4A
00
Press PAUSE (Write) button.
(9F)
8
F
4B
00
Press PAUSE (Write) button.
(9F)
9
0
10
00
10
0
01
00
11
In the following adjustment,
if the “Center frame” is used,
adjust the clear chart to this
position.
Fig.6-1-17
A clear chart must be shot in larger size
than central nine grids.