3-5
HDW-250
3-1. Setup Menu
CHAR OUT
Display on LCD
Setup item
Setup value
Description
CHAR V
CHARACTER V
0
Sets the vertical position on the screen display of the character
POSITION
:
information such as time code that is output from the ANALOG
22
HD COMPONENT (Y, P
B
, P
R
) connectors and the COMPOSITE
:
(NTSC) connector when the SUPERIMPOSE switch on the front
23
panel time code setting block, is set to the ON position. When 0
is set, the character information is displayed from the bottom end
of the screen display. As the number of character increases, it
moves upward. The numeral up to 23 can be set with 24 steps.
n
When the two-line character display is specified by the
sub-menu item “DISPLAY INFORMATION select”, the
characters of the second line can partially disappear on the
center of the screen.
CHAR TYPE
CHARACTER TYPE
without BG
Selects the character type of the character information such as
outlined
time code that is output from the ANALOG HD COMPONENT
translucent
(Y, P
B
, P
R
) connectors and the COMPOSITE (NTSC) connector
with BG
when the SUPERIMPOSE switch on the front panel time code
setting block, is set to the ON position.
Without BG : White characters without background
Outlined :
White characters with black outline
Translucent : White characters with translucent background
BG :
White characters with black background
n
When “translucent” is selected, the output signal from the
COMPOSITE connector is forced to be the “with BG” setup.
DISP INFO
DISPLAY
time data & status
Sets contents of the character information that is output from the
INFORMATION
time data & UB
ANALOG HD COMPONENT (Y, P
B
, P
R
) connectors and the
select
time data & CTL
COMPOSITE (NTSC) connector when the SUPERIMPOSE
time data & time data
switch on the front panel time code setting block, is set to the
time data only
ON position.
time data & status : Timer counter display information and
operating status
time data & UB : Timer counter display information and user’s bit
time data & CTL : Timer counter display information and CTL
time data & time data : Timer counter display information and VITC data
time data only : Timer counter display information only
CHAR WANG
CHAR WARNING
OFF
Selects whether or not to display the warning message on the
DISPLAY at dual
ON
second line by blinking when the sub-menu item “DISPLAY
line mode
INFORMATION select” is set to any positions other than “time
data only”.
OFF : Warning message is not displayed by blinking.
ON : Warning message is displayed by blinking when any
warning message exists.
m
.
The message that is canceled of its display, is not shown.
*
Refer to [Canceling the Warning Message Display] (on page
A-6 of Operation Manual.)
.
When two or more messages exist at the same time, the first
message is displayed by blinking twice then the other
message is displayed by blinking.
REMAIN TM
REMAIN TIME
OFF
Sets whether or not to display the remaining amount of tape as
ON
the character information that is output from the ANALOG HD
10 min
COMPONENT (Y, P
B
, P
R
) connectors and the COMPOSITE
(NTSC) connector when the SUPERIMPOSE switch on the front
panel time code setting block, is set to the ON position.
OFF :
Not displays remaining amount of tape.
ON :
Displays remaining amount of tape.
10 min : When the remaining amount of tape reaches 10
minutes or less, remaining amount of tape is displayed.
The items that are surrounded by square (
[|]
) in the Setup value column, show the default setting when shipped from the factory.