1-21
HDW-250
1-9. Setting Switches and Slit Lands on the Boards
CN301
CN601
CN302
CN304
CN303
1
2
3
4
E
F
G
D
C
B
A
CN913
CN912
CN911
CN305
1-9-4. EQ-76 Board
EQ-76 A SIDE
Ref. No.
Name
Description
Factory setting
S601-1
R/P ENV switch
Used during tape path adjustment
OFF
ON : Enables the R/P envelope detection
and turn off the power of both the EQ-76 board and
the drum
OFF : Normal use
S601-2
_
Factory use
OFF
S601-3
_
Factory use
OFF
S601-4
_
Factory use
OFF