91
5-4-8. Flare Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI 1 connector
Object: Grayscale chart
Preparation
•
Setting for the MSU
DETAIL OFF button
→
ON (unlit)
KNEE OFF button
→
OFF (lit)
MATRIX OFF button
→
OFF (lit)
•
Shoot the grayscale chart so that it is aligned with the under scanned monitor frame.
•
Lens iris: F4 to F5.6
•
A = 600 ±20 mV
If the lens aperture is greater than F5.6, adjust the light amount with the shutter.
Procedure
1. Operate the control panel of MSU, and set as follows.
(1) PAINT button
→
ON (lit)
(2) Touch panel operation: (Page 1)
→
[Flare]
2. Adjust the levels B to desired level for R, G and B respectively.
To adjust all levels for R, G and B simultaneously, adjust them using [Master].
•
Adjustment item : [R], [G], [B], [Master]
3. Store the reference file.
(Refer to “5-4-12. File Store”.)
A
B