78
6. Confirm the waveform of G channel in the verticalness direction, and adjust the lower level side finely, so that the step between
the left side and the right side of the waveform disappear.
ITEM: MONITOR SEL
→
G
•
Right side of waveform (waveform of lower side in full-white pattern)
ITEM: GAIN CONT [G1]
•
Left side of waveform (waveform of upper side in full-white pattern)
ITEM: GAIN CONT [G2]
7. Also adjust R and B channels finely in the same way as above step.
ITEM: GAIN CONT [R1], [R2]
ITEM: GAIN CONT [B1], [B2]
8. Repeat steps 2 to 7 to adjust sensitivity of G, R and B channels.
9. Store the file.
MENU: SERVICE
PAGE: OHB-ADJ1
ITEM: STORE FILE
Lower
side
Adjust the lower level
side finely.
The step between the left
side and the right side of
the waveform disappear.
Upper
side
V: FIELD
After adjustment
Before adjustment
Upper side
Lower side