5-4-7. Pedestal Level Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI 1 connector
Preparation
•
Setting for the MSU
CLOSE button
→
ON (lit)
Procedure
1. Operate the control panel of MSU, and set as follows.
(1) PAINT button
→
ON (lit)
(2) Touch panel operation: (Page 1)
→
[Black]
2. Adjust the levels A to desired level for R, G and B respectively.
To adjust all levels for R, G and B simultaneously, adjust them using [Master].
•
Adjustment item: [R], [G], [B], [Master]
•
Reference value: A = 21 mV
3. Store the reference file.
(Refer to “5-4-12. File Store”.)
A