5-7
3-1-2.
Precautions on Adjusting
1)
Disconnecting the VC-250 board CN926 (4P, 0.8mm) means
disconnecting the lithium 3V power supply (FP-571 board
BT001), data such as date, time, user-set menus will be lost.
After completing adjustments, reset these data. If the CN926
has been disconnected, the self-diagnosis data, data on history
of use (total drum rotation time etc.) will be lost. Before
disconnecting, note down the self-diagnosis data (data of page:
2, address: B0 to C6) and data on history use (data of page: 2,
address: A2 to AA). (Refer to “5-4. SERVICE MODE” for the
self-diagnosis data and the data on the history use.)
2)
To remove the cabinet (upper) and LCD block (GV-D800/
D800E only), disconnect the following connectors.
VC-250 board CN926 (4P 0.8mm)
(Lithium battery)
VC-250 board CN931 (40P 0.5mm)
(EX-36 board (Multi connector))
VC-250 board CN929 (5P 0.8mm)
(DV jack)
VC-250 board CN923 (32P 0.5mm) (GV-D800/D800E
only)
(PD-130 board (LCD panel)
VC-250 board CN924 (10P 0.5mm)
(IR-38 board (IR transmitter))
VC-250 board CN922 (50P 0.5mm)
(IO-68 board, FP-575 flexibles, FP-246 flexible)
As the video and audio jacks and LANC jack are provided on
the IO-68 board and the power switch is provided on the FP-
575 flexible board, these boards must be connected to the VC-
250 board. So remove the cabinet (R) assembly (IO-68 board
and FP-575 flexible and FP-246 flexible) from the cabinet
(upper) assembly and connect it to the following connector.
VC-250 board CN922 (50P 0.5mm)
3)
By setting the “Forced VTR Power ON mode”, the video section
can be operate even if the FP-575 flexible board (power switch)
has been removed.
Note 1:
Setting the “Forced VTR Power ON” mode (VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the VTR power to be turned
on with the FP-575 flexible board removed.
After completing adjustments, be sure to exit the “Forced VTR
Power ON mode”.
Note 2:
Exiting the “Forced Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
3-1-3.
Adjusting Connectors
Some of the adjusting points of the video section are concentrated
at VC-250 board CN933. Connect the measuring instruments via
the CPC-13 jig (J-6082-443-A). The following table lists the pin
numbers and signal names of CN933.
Table. 5-3-1.
Pin No.
1
2
3
4
5
6
7
8
9
10
Signal Name
SWP
AFC F0
BPF MONI
FO ADJ RF IN
PB RF
REG GND
RF AGC OUT
VC RF SWP
NC
NC
Pin No.
11
12
13
14
15
16
17
18
19
20
Signal Name
NC
NC
DV RF SWP
RF IN
CAP FG
RF MON
TMS
TCK
TDO
TDI
Fig. 5-3-1.
VC-250 board
CN933
20
1
Summary of Contents for GV-D200E
Page 11: ...1 2 ...
Page 12: ...1 3 ...
Page 13: ...1 4 ...
Page 14: ...1 5 ...
Page 15: ...1 6 ...
Page 16: ...1 7 ...
Page 17: ...1 8 ...
Page 18: ...1 9 ...
Page 19: ...1 10 ...
Page 20: ...1 11 ...
Page 21: ...1 12 ...
Page 22: ...1 13 ...
Page 23: ...1 14 ...
Page 24: ...1 15 ...
Page 25: ...1 16 ...
Page 26: ...1 17 ...
Page 27: ...1 18 ...
Page 28: ...1 19 ...
Page 29: ...1 20 ...
Page 30: ...1 21 ...
Page 31: ...1 22 ...
Page 32: ...1 23E ...