5-21
3. Switching Position Adjustment (VC-250 Board)
To obtain normal playback waveform output during the Digital8
playback mode, adjust the switching position.
Mode
VTR playback
Signal
SW/OL reference tape (WR5-2D)
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
10, 11, 12, 13
Specified Value
00
Adjusting method:
Order Page Address Data
Procedure
1
Insert the SW/OL reference tape
and enter the VTR STOP mode.
2
0
01
01
Set the data.
3
3
21
Check that the data is “02”.
(Note1)
4
3
01
0D
Set the data, and press PAUSE
button.
5
3
02
Check that the data changes to
“00”.
6
3
03
Check that the data is “00”.
(Note2)
7
C
10
Check that the data is other than
“EE”. (Note3)
8
0
01
00
Set the data.
Note 1:
If the data of page: 3, address: 21 is “72”, the tape top being played.
After playing the tape for 1 to 2 seconds, perform step 4 and higher.
Note 2:
If bit 0 of the data is “1”, the A channel is defective. If bit 1 is “1”,
the B channel is defective. Contents of the defect is written into
page: C, addresses: 10 and 12. See the following table. (For the bit
values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit value
discrimination”. )
Note 3:
If the data is “EE” rewind the tape and repeat steps 1 to 7.
When the A channel is defective
Data of page:C,
Contents of defect
address:10
EE
Writing into EEPROM (IC4502) is
defective
E8
Adjustment data is out of range
E7
No data is returned from IC3301
(CAIN)
When the B channel is defective
Data of page:C,
Contents of defect
address:12
EE
Writing into EEPROM (IC4502) is
defective
E8
Adjustment data is out of range
E7
No data is returned from IC3301
(CAIN)
4. AGC Center Level and APC & AEQ Adjustment
4-1. Preparations before adjustments
Mode
Recording
Signal
Color bar
Note:
Use a Hi8 MP tape.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
8
2A
C8
Set the data.
3
Record the color bar signal for
three minutes.
4-2. AGC Center Level Adjustment (VC-250 Board)
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
Measurement Point
Pin
qh
of CN933 (RF MON) (Note 1)
Ext. trigger: Pin
qd
of CN933 (DV RFSWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
1E
Specified Value
The data of page: 3, address: 03 is “00”
Note 1:
Connect a 75
Ω
resistor between Pin
qh
and Pin
6
(GND) of CN933.
75
Ω
resistor (Parts code: 1-247-804-11)
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations before adjustments”
2
0
01
01
Set the data.
3
2
2E
01
Set the data.
4
3
33
08
Set the data.
5
Confirm that the playback RF
signal is stable. (Fig. 5-3-5.)
6
3
01
23
Set the data, and press PAUSE button.
7
3
02
Check that the data is “00”.
8
3
03
Check that the data is “00”.
(Note2)
9
Perform “APC & AEQ Adjustment”.
Note 2:
If the data of page: 3, address: 03 is other than “00”, adjustment
has errors.
13.3 msec
PB RF signal is stable
Pin
qd
Pin
qh
Fig. 5-3-5.
Summary of Contents for GV-D200E
Page 11: ...1 2 ...
Page 12: ...1 3 ...
Page 13: ...1 4 ...
Page 14: ...1 5 ...
Page 15: ...1 6 ...
Page 16: ...1 7 ...
Page 17: ...1 8 ...
Page 18: ...1 9 ...
Page 19: ...1 10 ...
Page 20: ...1 11 ...
Page 21: ...1 12 ...
Page 22: ...1 13 ...
Page 23: ...1 14 ...
Page 24: ...1 15 ...
Page 25: ...1 16 ...
Page 26: ...1 17 ...
Page 27: ...1 18 ...
Page 28: ...1 19 ...
Page 29: ...1 20 ...
Page 30: ...1 21 ...
Page 31: ...1 22 ...
Page 32: ...1 23E ...