5-4
5-2. MECHANISM SECTION
ADJUSTMENT
Mechanism Section adjustments, checks, and replacement of
mechanism parts, refer to the separate volume “8mm Video
Mechanism Adjustment Manual
B Mechanism ”.
Note 1:
NTSC model: GV-D200/D800
PAL model: GV-D200E/D800E
2-1.
Hi8/STANDARD8 MODE
2-1-1.
OPERATING WITHOUT CASSETTE
1)
Refer to “Section 2. DISASSEMBLY” and supply the power
with the cabinet assembly removed. (So that the mechanical
deck can be operated.)
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Close the cassette compartment without loading a cassette and
complete loading.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: F, address: 22, set data: 81, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: D, address: 10, set data: 10, and press the PAUSE
button of the adjustment remote commander.
8)
Disconnect the power supply of the unit.
By carrying out the above procedure, the unit can be operated
without loading a cassette. (Note2)
Be sure to carry out “Processing after Operations” after
checking the operations.
Set the data of page: D, address: 10 to “12”, if the sensor
ineffective mode, forced VTR power supply ON mode is to be
used together.
Note 2:
Except for the recording mode.
[Procedure after checking operations]
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 22, set data: 80, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Disconnect the power supply of the unit.
2-1-2.
TAPE PATH ADJUSTMENT
1. Preparations for Adjustment
1)
Clean the tape path face (tape guide, capstan shaft, pinch roller).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: 2, address: 2E, and set data: 02.
6)
Select page: F, address: 22, set data: 88, and press the PAUSE
button of the adjustment remote commander.
(Be sure to perform “Processing after operation” after
completing adjustments.)
7)
Connect the oscilloscope to VC-250 board CN933 via CPC-13
jig (J-6082-443-A).
Channel 1: VC-250 board, CN933 Pin
5
External trigger: VC-250 board, CN933 Pin
8
8)
Playback Hi8/standard8 alignment tape for tracking.
(WR5-1NP(NTSC))
(WR5-1CP(PAL))
9)
Check that the oscilloscope RF waveform is flat at the entrance
and exit.
If not flat, adjust according to the separate volume “8mm Video
Mechanical Adjustment Manual
B Mechanism ”.
10) Perform “Processing after operations”, after completing
adjustment.
CN933 of VC-250board
Table 5-2-1.
[Procedure after operations]
1)
Connect the adjustment remote commander, and turn on the
HOLD switch.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 2, address: 2E, and set data: 00.
4)
Select page: F, address: 22, set data: 80, and press the PAUSE
button of the adjustment remote commander.
5)
Select page: 0, address: 01, and set data: 00.
6)
Remove the power supply from the unit.
Fig. 5-2-1.
Pin No.
1
2
3
4
5
6
7
8
9
10
Signal Name
SWP
AFC F0
BPF MONI
F0 ADJ RF IN
PB RF
REG GND
RF AGC OUT
VC RF SWP
NC
NC
Pin No.
11
12
13
14
15
16
17
18
19
20
Signal Name
NC
NC
DV RF SWP
RF IN
CAP FG
RF MON
TMS
TCK
TDO
TDI
Must be flat
Summary of Contents for GV-D200E
Page 11: ...1 2 ...
Page 12: ...1 3 ...
Page 13: ...1 4 ...
Page 14: ...1 5 ...
Page 15: ...1 6 ...
Page 16: ...1 7 ...
Page 17: ...1 8 ...
Page 18: ...1 9 ...
Page 19: ...1 10 ...
Page 20: ...1 11 ...
Page 21: ...1 12 ...
Page 22: ...1 13 ...
Page 23: ...1 14 ...
Page 24: ...1 15 ...
Page 25: ...1 16 ...
Page 26: ...1 17 ...
Page 27: ...1 18 ...
Page 28: ...1 19 ...
Page 29: ...1 20 ...
Page 30: ...1 21 ...
Page 31: ...1 22 ...
Page 32: ...1 23E ...