5-5
2-2.
DIGITAL8 MODE
2-2-1.
HOW TO ENTER RECORD MODE WITHOUT
CASSETTE
1)
Connect the adjustment remote commander to the LANC jack.
2)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
3)
Close the cassette compartment without the cassette.
4)
Select page: 3, address: 01, and set data: 0C, and press the
PAUSE button of the adjustment remote commander.
(The mechanism enters the record mode automatically.)
Note:
The function buttons becomes inoperable.
5)
To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander. (Whenever you want to quit the record mode, be
sure to quit following this procedure.)
2-2-2.
HOW TO ENTER PLAYBACK MODE WITHOUT
CASSETTE
1)
Connect the adjustment remote commander to the LANC jack.
2)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
3)
Close the cassette compartment without the cassette.
4)
Select page: 3, address: 01, and set data: 0B, and press the
PAUSE button of the adjustment remote commander.
(The mechanism enters the playback mode automatically.)
Note:
The function buttons becomes inoperable.
5)
To quit the playback mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander. (Whenever you want to quit the playback mode,
be sure to quit following this procedure.)
2-2-3.
OVERALL TAPE PATH CHECK
1. Recording of the tape path check signal
1)
Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2)
Input a color bar signal to the AUDIO/VIDEO INPUT jack.
3)
Connect the adjustment remote commander to the LANC jack.
4)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
5)
Set to the recording mode.
6)
Select page: 3, address: 1C, set data: 5D, and press the PAUSE
button of the adjustment remote commander.
7)
Record for several minutes.
8)
Release the recording mode.
9)
Select page: 3, address: 1C, set data: 00, and press the PAUSE
button.
2. Tape path check
1)
Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
4)
Connect an oscilloscope to VC-250 board CN933 via the CPC-
13 jig (J-6082-443-A).
Channel 1: VC-250 board, CN933 Pin
qh
(Note)
External trigger: VC-250 board, CN933 Pin
qd
Note:
Connect a 75
Ω
resistor between Pins
qh
of CN910 and
6
(GND).
5)
Select page: 2, address: 2E, and set data: 01.
6)
Playback the tape path check signal.
7)
Select page: 3, address: 33, and set data: 08.
8)
Select page: 3, address: 26, and set data: 31.
9)
Check that the oscilloscope RF waveform is flat at the entrance
and exit.
If not flat, perform “2-1-2. TAPE PATH ADJUSTMENT “ of
“2-1. Hi8/STANDARD 8mm MODE”.
10) Select page: 3, address: 26, and set data: 00.
11) Select page: 3, address: 33, and set data: 00.
12) Select page: 2, address: 2E, and set data: 00.
Fig. 5-2-2.
Must be flat
Pin
qd
Pin
qh
Summary of Contents for GV-D200E
Page 11: ...1 2 ...
Page 12: ...1 3 ...
Page 13: ...1 4 ...
Page 14: ...1 5 ...
Page 15: ...1 6 ...
Page 16: ...1 7 ...
Page 17: ...1 8 ...
Page 18: ...1 9 ...
Page 19: ...1 10 ...
Page 20: ...1 11 ...
Page 21: ...1 12 ...
Page 22: ...1 13 ...
Page 23: ...1 14 ...
Page 24: ...1 15 ...
Page 25: ...1 16 ...
Page 26: ...1 17 ...
Page 27: ...1 18 ...
Page 28: ...1 19 ...
Page 29: ...1 20 ...
Page 30: ...1 21 ...
Page 31: ...1 22 ...
Page 32: ...1 23E ...