— 6 —
SERVICE NOTE
1.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied (8.4V) to the battery terminal using the service power code (J-6082-223-A), the power
is shut off so that the unit cannot operate.
These following two methods are available to prevent this. Take note of which to use during repairs.
Method 1:
Connect the adjustment remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the HOLD switch to the “ADJ” side.
Method 2:
Use the DC IN terminal. (Use the AC power adaptor. (AC-L10, AC-VQ800 etc.))
2.
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT) (1)
1
Remove the power supply (Battery or AC power adaptor).
2
Push the EJECT switch and open the cassette lid.
3
Refer to 2-2. to remove the cabinet (lid) assembly.
4
Refer to 2-2. to remove the cabinet (bottom) assembly.
5
Add 5V from the regulated power supply between Pin
5
,
6
of CN4401 (ULD5V +) and Pin
7
,
8
of CN4401 (ULD5V –), and unload
the cassette.
Regulated
power supply (+5V)
VC-250 board
CN4401
1
ULD
5V
8