5-24
7. CAP FG Offset Adjustment (VC-250 board)
Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur in the Hi8/Standard8 LP mode.
Mode
Playback
Signal
Hi8/standard 8 alignment tape :
For checking operation
(WR5-5NSP(NTSC))
(WR5-5CSP(PAL))
Measurement Point
Pin
qg
of CN933 (CAP FG)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
64
Specified value
Duty = 50 ± 1 %
Adjusting method:
Order Page Address Data
Procedure
1
Set to the stop mode.
2
0
01
01
Set the data.
3
2
0E
02
Set the data.
4
Set to the playback mode.
5
6
01
81
Set the data, and press PAUSE
button.
6
3
02
Check that the data changes to
“01”.
7
6
01
00
Set the data, and press PAUSE
button.
8
Check that Duty of CAP FG
signal satisfies the specified
value. If not, repeat steps 5 to 8.
9
2
0E
00
Set the data.
10
0
01
00
Set the data.
Fig. 5-3-8.
A
B
Duty = A/B
×
100 [%]
Center of movement
Summary of Contents for GV-D200E
Page 11: ...1 2 ...
Page 12: ...1 3 ...
Page 13: ...1 4 ...
Page 14: ...1 5 ...
Page 15: ...1 6 ...
Page 16: ...1 7 ...
Page 17: ...1 8 ...
Page 18: ...1 9 ...
Page 19: ...1 10 ...
Page 20: ...1 11 ...
Page 21: ...1 12 ...
Page 22: ...1 13 ...
Page 23: ...1 14 ...
Page 24: ...1 15 ...
Page 25: ...1 16 ...
Page 26: ...1 17 ...
Page 27: ...1 18 ...
Page 28: ...1 19 ...
Page 29: ...1 20 ...
Page 30: ...1 21 ...
Page 31: ...1 22 ...
Page 32: ...1 23E ...