5-16
2.
Flange Back Adjustment (Using the minipattern box)
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
Mode
CAMERA
Subject
Siemens star chart with ND filter
for minipattern box (Note 1)
Measurement Point
Check operation on the LCD
Measuring Instrument
screen
Adjustment Page
F
Adjustment Address
14 to 25
Note 1:
Dark Siemens star chart.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
ure.
Note 3:
The attachment lenses are not used.
Note 4:
Take care not to hit the mini-pattern box when
extending the lens.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage
±
0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
6) Check that the data on page: F, address: 14 to 25 are initial
value (See table below).
Specified voltage: The specified voltage varies according to the
minipatternbox, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Minipattern box
Below 3 cm
Camera
Camera
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage
±
0.01 Vdc
Output current : more than 3.5 A
Fig. 5-1-13
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
4
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
5
6
01
13
Press PAUSE button.
6
6
01
27
Press PAUSE button. (Note 5)
7
6
02
Check the data changes to “01”.
Note 5:
The adjustment data will be automatically input to page:
F, address: 14 to 25.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
5
F1
00
3
D
63
00
Press PAUSE button.
4
Release the data setting
performed at step 4. (Refer to
page 5-14)
5
0
01
00
6
Perform“Flange Back Check”.
Address
Data
Address
Data
14
12
1D
00
15
A8
1E
41
16
38
1F
00
17
08
20
20
18
17
21
20
19
67
22
20
1A
00
23
44
1B
00
24
0A
1C
00
25
00