5-33
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
F
DE
Set data noted down at step
5, and press PAUSE button.
2
F
E3
Set data noted down at step
7, and press PAUSE button.
3
6
01
00
Press PAUSE button.
4
5
F1
00
5
D
63
00
Press PAUSE button.
6
Release the data setting
performed at step 4.
(Refer to page 5-14)
7
0
01
00
19. CCD White Defect Compensation
Mode
CAMERA
Subject
Clear chart
(25 cm from the front of lens)
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
7
Adjustment Address
88 to A3
Note 1:
Check that there are no dust, no dirt and reflection of the
clear chart.
Note 2:
Any subject other than the clear chart should be in the
screen.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
FF
3
D
63
40
Press PAUSE button.
4
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
5
F
DE
Note down the data.
6
F
DE
1E
Press PAUSE button.
7
F
E3
Note down the data.
8
F
E3
18
Press PAUSE button.
9
6
01
8B
Press PAUSE button. (Note 3)
10
6
02
Check the data changes to “01”.
11
6
55
Check the data.
00 to 7F: Normal
80 to FF: Defective
12
6
01
00
Press PAUSE button.
13
F
DE
0F
Press PAUSE button.
14
F
E3
A0
Press PAUSE button.
15
6
01
87
Press PAUSE button.
16
6
02
Check the data changes to “01”.
17
6
55
Check the data.
00: Normal
01 to FF: Defective
Note 3:
The adjustment data will be automatically input to page:
7, address: 88 to A3.