5-46
6. Color Adjustment (FC-85 Board)
Set the color saturation to the standard value.
If, deviated, the color will be dark or light.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin
9
of CN803 (VG)
External trigger: Pin
8
of CN803
(COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D1
Specified Value
A = 480
±
50 mVp-p (TYPE S)
A = 360
±
50 mVp-p (TYPE C)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
04
3
D
D1
Change the data and set the
voltage (A) to the specified value.
4
D
D1
Press PAUSE button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
5
F1
00
2
0
01
00
Fig. 5-1-32
A
2H
Green
White 100%
A: Between the white 100% (Reference level)
and green
Fig. 5-1-33
A
2H
7. V-COM Level Adjustment (FC-85 Board)
Set the common electrode drive signal level of LCD to the speci-
fied value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin
8
of CN803 (COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D6
Specified Value
A = 6.50
±
0.05 Vp-p (TYPE S)
A = 5.65
±
0.05 Vp-p (TYPE C)
Adjusting method:
Order Page Address Data
Procedur
1
0
01
01
2
5
F1
03
3
D
D6
Change the data and set the
VCOM signal level (A) to the
specified value.
4
D
D6
Press PAUSE button.
Processing after Completing Adjustment:
Order Page Address Data
Procedur
1
5
F1
00
2
0
01
00