5-41
6. White Balance Adjustment (VF-141 board)
Correct the white balance.
If deviated, the EVF screen color cannot be reproduced.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Check on the EVF display
Measuring Instrument
Adjustment Page
D
Adjustment Address
C1, C2
Specified Value
The EVF screen should not be
colored.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
02
3
D
C1
A8
Press PAUSE button. (Initial
C2
78
value)
4
Check that the EVF screen is not
colored, If not colored, proceed to
“Processing after Completing
Adjustments”
5
D
C1
Change the data and so that the
EVF screen is not colored.
C2
(Note)
Note:
To write in the non-volatile memory (EEPROM), press
the PAUSE button each time to set the data.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
5
F1
00
2
0
01
00
5. Backlight Consumption Current Adjustment
(VF-141 board)
Set the backlight luminance and color temperature.
If deviated, the image may become dark or bright.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
+Probe: Pin
w;
of CN803
(EVF_BL_4.75 V) on FC-85 board
-Probe: Pin
ql
of CN803 (EVF_BL)
on FC-85 board
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
C6
Specified Value
A = 15.0
±
1 mV
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
5
F1
02
3
D
C6
Change the data and set the DC
voltege (A) to the specified value.
4
D
C6
Press PAUSE button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
5
F1
00
2
0
01
00