6-17
2-3-6. FLD Grid Test Display and SHUTTLE Click Operation
Test
2-3-6-1. Transition Keys in Self Check Mode
•
R
key on the remote commander
• SHUTTLE on the remote commander during Grid Test display
(This unit does not provide JOG/SHUTTLE, and therefore use
another DVD remote commander having the JOG/SHUTTLE)
2-3-6-2. Operation and Display
The Self Check Mode transits to this mode when
R
key is entered.
This tests whether each grid turns on individually. The first grid only
of FLD turns on and other grid turn off. Each time the SHUTTLE is
entered, the grid is switched in order. When SHUTTLE input is
clockwise, the grid switched in 1 - 2 - 3 direction, or counterclockwise
it switches in 3 - 2 - 1 direction.
• Display at the start of Grid Test
2-3-7. LED Test Display
2-3-7-1. Transition Keys in Self Check Mode
•
r
key on the remote commander
• SHUTTLE on the remote commander during Grid Test display
(This model does not provide JOG/SHUTTLE, and therefore use
another DVD remote commander having the JOG/SHUTTLE)
2-3-7-2. Operation and Display
LED is switched in order by the input JOG/SHUTTLE on the remote
commander. Aslo, LED ON/OFF is switched by the input of same key
as the function that turns on the LED conncerned.
• FLD display during LED Test
r
(Input in CW direction)
Summary of Contents for DVP NS725P - Progressive-Scan DVD/CD Player
Page 7: ... 7 6 Set complete Fig 6 ...
Page 8: ... 8 MEMO 8E ...
Page 46: ...2 6 2 10 INTERNAL VIEWS MS128 MOUNT TOPVIEW BOTTOMVIEW Optical Device KHM 290AAA A 6061 908 A ...
Page 48: ...2 8 2 8E ...
Page 88: ...DVP NS325 NS330 NS333 NS430 NS433 NS530 NS725P NS730P 4 59 4 60E ...
Page 112: ...6 22 6 22E ...