5-26
8. IRIS IN/OUT Adjustment
For the unit to judge if the white balance is indoors or outdoors in
auto white balance operations, measure the light level and write it
in the EEPROM.
If the level is not correct, the white balance will not be accurate.
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
DDS display of EVF or LCD or TV
monitor (Note)
Measuring Instrument
Adjustment Page
F
Adjustment Address
56, 57
Note:
The right four digits of the DDS display data of EVF or LCD or TV
monitor.
CAM 00 00 00
CAM 00 XX XX
Lower two digits
Upper two digits
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 0, address: 03, and set data: 06.
3)
Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 40, and set data: 02.
5)
Select page: 6, address: 01, set data: 0B, and press the PAUSE
button.
6)
Read the DDS display data (Note), and take the upper two digits
as D
1
and the lower two as D
2
.
7)
Convert D
1
to decimal notation, and obtain D
1
'. (Refer to Table
5-4-1. “Hexadecimal - decimal conversion table” of “5-4.
Service Mode”.)
8)
Calculate D
3
' using the following equations. (Equations 1 and
2 are for decimal notation calculation).
When D
2
D0
D
3
' = D
1
' – 21
Equation 1
When D
2
< D0
D
3
' = D
1
' – 22
Equation 2
9)
Convert D
3
' to hexadecimal notation, and obtain D
3
.
10) Select page: F, address: 56, set data: D
3
, and press the PAUSE
button.
11) Select page: 6, address: 01, set data: 09, and press the PAUSE
button.
12) Read the DDS display data (Note), and take the upper two digits
as D
4
and the lower two as D
5
.
13) Convert D
4
to decimal notation, and obtain D
4
'. (Refer to Table
5-4-1. “Hexadecimal - decimal conversion table” of “5-4.
Service Mode”.)
14) Calculate D
6
' using the following equations. (Equations 3 and
4 are for decimal notation calculation).
When D
5
F0
D
6
' = D
4
' – 13
Equation 3
When D
5
< F0
D
6
' = D
4
' – 14
Equation 4
15) Convert D
6
' to hexadecimal notation, and obtain D
6
.
16) Select page: F, address: 57, set data: D
6
, and press the PAUSE
button.
Processing after Completing Adjustments
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 0, address: 03, and set data: 00.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)
Select page: 6, address: 40, and set data: 00
Summary of Contents for Digital8 DCR-TRV410
Page 12: ...1 2 ...
Page 13: ...1 3 ...
Page 14: ...1 4 ...
Page 15: ...1 5 ...
Page 16: ...1 6 ...
Page 17: ...1 7 ...
Page 18: ...1 8 ...
Page 19: ...1 9 ...
Page 20: ...1 10 ...
Page 21: ...1 11 ...
Page 22: ...1 12 ...
Page 23: ...1 13 ...
Page 24: ...1 14 ...
Page 25: ...1 15 ...
Page 26: ...1 16 ...
Page 27: ...1 17 ...
Page 28: ...1 18 ...
Page 29: ...1 19 ...
Page 30: ...1 20 ...
Page 31: ...1 21 ...
Page 32: ...1 22 ...
Page 33: ...1 23 ...
Page 34: ...1 24 ...
Page 35: ...1 25 ...
Page 36: ...1 26 ...
Page 37: ...1 27 ...
Page 38: ...1 28 ...
Page 39: ...1 29 ...
Page 40: ...1 30 ...
Page 41: ...1 31 ...
Page 42: ...1 32 ...
Page 43: ...1 33E ...
Page 56: ...DCR TRV410 TRV410E TRV510 TRV510E 3 2 OVERALL BLOCK DIAGRAM 2 3 4 3 5 3 6 ...
Page 58: ...DCR TRV410 TRV410E TRV510 TRV510E 3 10 3 11 3 12E 3 4 POWER BLOCK DIAGRAM 2 ...
Page 79: ...DCR TRV410 TRV410E TRV510 TRV510E 4 73 4 74 STEADY SHOT SE 88 AV IN OUT PJ 97 ...
Page 83: ...DCR TRV410 TRV410E TRV510 TRV510E 4 83 4 84 4 85 USER CONTROL CF 64 ...