5-48
3. AGC Center Level Adjustment (VC-213 board)
Mode
Camera record and playback
Subject
Arbitrary
Measurement Point
Pin
!§
of CN910 (RF MON) (Note 1)
External trigger : Pin
!£
of CN910
(DV RF SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
1E
Specified Value
The display data of page: 3, address:
03 is “00”
Note 1:
Connect a 75
Ω
resistor between Pin
!§
and Pin
6
(GND) of CN910.
75
Ω
resistor (Parts code: 1-247-804-11)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: C, address: 54, set data: C8, and press the PAUSE
button of the adjustment remote commander.
3)
Record the camera signal for a minute.
4)
Select page: 2, address: 2E, and set data: 01.
5)
Playback the recorded segment.
6)
Select page: 3, address: 33, and set data: 08.
7)
Confirm that the playback RF signal is stable.
8)
Select page: 3, address: 01, set data: 23, and press the PAUSE
button.
9)
Select page: 3, address: 02, and check that the data is “00”.
10) Select page: 3, address: 03, and check that the data is “00”.
Note 2 :
If the data of page: 3, address: 03 is other than “00”,
adjustment has errors.
11) Select page: 3, address: 33, and set data: 00.
12) Select page: 2, address: 2E, and set data: 00.
13) Select page: C, address: 54, set data: CC, and press the PAUSE
button.
14) Select page: 0, address: 01, and set data: 00.
4. APC & AEQ Adjustment (VC-213 board)
Mode
Camera record and playback
Subject
Arbitrary
Measurement Point
Pin
!§
of CN910 (RF MON) (Note 1)
External trigger : Pin
!£
of CN910
(DV RF SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
18, 19, 1B, 1C, 21, 73
Specified Value
The display data of page: 3, address:
03 is “00”
Note 1:
Connect a 75
Ω
resistor between Pin
!§
and Pin
6
(GND) of CN2904.
75
Ω
resistor (Parts code: 1-247-804-11)
Note 2:
Use a Hi8 MP tape.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: C, address: 54, set data: C8, and press the PAUSE
button of the adjustment remote commander.
3)
Record the camera signal for a minute.
4)
Select page: 2, address: 2E, and set data: 01.
5)
Playback the recorded segment.
6)
Select page: 3, address: 33, and set data: 08.
7)
Confirm that the playback RF signal is stable.
8)
Select page: 3, address: 01, set data: 07, and press the PAUSE
button.
9)
Select page: 3, address: 02, and check that the data changes
from “07” to “00” in about 20 seconds after pressing the PAUSE
button.
10) Select page: 3, address: 03, and check that the data is “00”.
Note 3:
If the data of page: 3, address: 03 is other than “00”,
adjustment has errors.
11) Select page: 3, address: 33, and set data: 00.
12) Select page: 2, address: 2E, and set data: 00.
13) Select page: C, address: 54, set data: CC, and press the PAUSE
button.
14) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-5.
13.3 msec
PB RF signal is stable
Pin
!£
Pin
!§
Fig. 5-3-6.
13.3 msec
PB RF signal is stable
Pin
!£
Pin
!§
Summary of Contents for Digital8 DCR-TRV410
Page 12: ...1 2 ...
Page 13: ...1 3 ...
Page 14: ...1 4 ...
Page 15: ...1 5 ...
Page 16: ...1 6 ...
Page 17: ...1 7 ...
Page 18: ...1 8 ...
Page 19: ...1 9 ...
Page 20: ...1 10 ...
Page 21: ...1 11 ...
Page 22: ...1 12 ...
Page 23: ...1 13 ...
Page 24: ...1 14 ...
Page 25: ...1 15 ...
Page 26: ...1 16 ...
Page 27: ...1 17 ...
Page 28: ...1 18 ...
Page 29: ...1 19 ...
Page 30: ...1 20 ...
Page 31: ...1 21 ...
Page 32: ...1 22 ...
Page 33: ...1 23 ...
Page 34: ...1 24 ...
Page 35: ...1 25 ...
Page 36: ...1 26 ...
Page 37: ...1 27 ...
Page 38: ...1 28 ...
Page 39: ...1 29 ...
Page 40: ...1 30 ...
Page 41: ...1 31 ...
Page 42: ...1 32 ...
Page 43: ...1 33E ...
Page 56: ...DCR TRV410 TRV410E TRV510 TRV510E 3 2 OVERALL BLOCK DIAGRAM 2 3 4 3 5 3 6 ...
Page 58: ...DCR TRV410 TRV410E TRV510 TRV510E 3 10 3 11 3 12E 3 4 POWER BLOCK DIAGRAM 2 ...
Page 79: ...DCR TRV410 TRV410E TRV510 TRV510E 4 73 4 74 STEADY SHOT SE 88 AV IN OUT PJ 97 ...
Page 83: ...DCR TRV410 TRV410E TRV510 TRV510E 4 83 4 84 4 85 USER CONTROL CF 64 ...