5-53
2. Hi8/standard 8 mm AFM 1.5 MHz Deviation
Adjustment (VC-235 board)
Adjust to the optimum 1.5 MHz audio FM signal deviation.
If the adjustment is not correct, its playback level will differ from
that of other units.
Mode
Playback
Signal
Hi8/standard 8 mm alignment tape:
For checking AFM stereo operation
Monoscope section
(WR5-9NS(NTSC))
(WR5-9CS(PAL))
Measurement Point
Audio left or right terminal of A/V
jack
Measuring Instrument
Audio level meter
Adjustment Page
F
Adjustment Address
7B
Specified Value
–7.5 ± 2.0 dBs
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Set the Hi-Fi sound switch (menu display) to “1”.
3)
Select page: F, address: 7B, change the data and set the 400 Hz
signal level to the specified value.
4)
Press the PAUSE button.
5)
Set the Hi-Fi sound switch (menu display) to “STEREO”.
6)
Select page: 0, address: 01, and set data: 00.
3. Hi8/standard 8 mm AFM 1.7 MHz Deviation
Adjustment (VC-235 board)
Adjust to the optimum 1.7 MHz audio FM signal deviation.
If improper, this causes deteriorated separation (with stereo signal).
Mode
Playback
Signal
Hi8/standard 8 mm alignment tape:
For checking AFM stereo operation
Monoscope section
(WR5-9NS(NTSC))
(WR5-9CS(PAL))
Measurement Point
Audio left or right terminal of A/V
jack
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
7C
Specified Value
–7.5 ± 2.0 dBs
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Set the Hi-Fi sound switch (menu display) to “2”.
3)
Select page: F, address: 7C, change the data and set the 1 kHz
signal level to the specified value.
4)
Press the PAUSE button.
5)
Set the Hi-Fi sound switch (menu display) to “STEREO”.
6)
Select page: 0, address: 01, and set data: 00.
4. Digital8 Playback Level Check
Mode
VTR playback
Signal
Digital8 alignment tape:
For audio operation check
(WR5-3ND (NTSC))
(WR5-3CD (PAL))
Measurement Point
Audio left or right terminal of A/V
jack
Measuring Instrument
Audio level meter and frequency counter
Specified Value
32 kHz mode: 1 kHz, + 3.0 ± 2.0 dBs
48 kHz mode: 1 kHz, + 3.0 ± 2.0 dBs
44.1 kHz mode:
The 7.35 kHz signal level during EMP
OFF is +2.0 ± 2.0 dBs.
The 7.35 kHz signal level during EMP
ON is –6 ± 2 dB from the signal level
during EMP OFF.
Checking Method:
1)
Check that the playback signal level is the specified value.
5. Overall Level Characteristics Check
Mode
Camera recording and playback
Signal
400 Hz, –66 dBs signal: MIC jack left
and right
Measurement Point
Audio left or right terminal of A/V
jack
Measuring Instrument
Audio level meter
Specified Value
–7.5 ± 3.0 dBs
Checking Method:
1)
Input the 400 Hz, –66 dBs signal in the MIC jack.
2)
Record in the camera mode.
3)
Playback the recorded section.
4)
Check that the 400 Hz signal level is the specified value.
6. Overall Distortion Check
Mode
Camera recording and playback
Signal
400 Hz, –66 dBs signal: MIC jack left
and right
Measurement Point
Audio left or right terminal of A/V
jack
Measuring Instrument
Audio distortion meter
Specified Value
Below 0.4%
(200 Hz to 6 kHz BPF ON)
Checking Method:
1)
Input the 400 Hz, –66 dBs signal in the MIC jack.
2)
Record in the camera mode.
3)
Playback the recorded section.
4)
Check that the distortion is the specified value.
Summary of Contents for DCR-TRV120P
Page 13: ...1 2 ...
Page 14: ...1 3 ...
Page 15: ...1 4 ...
Page 16: ...1 5 ...
Page 17: ...1 6 ...
Page 18: ...1 7 ...
Page 19: ...1 8 ...
Page 20: ...1 9 ...
Page 21: ...1 10 ...
Page 22: ...1 11 ...
Page 23: ...1 12 ...
Page 24: ...1 13 ...
Page 25: ...1 14 ...
Page 26: ...1 15 ...
Page 27: ...1 16 ...
Page 28: ...1 17 ...
Page 29: ...1 18 ...
Page 30: ...1 19 ...
Page 31: ...1 20 ...
Page 32: ...1 21 ...
Page 33: ...1 22 ...
Page 34: ...1 23 ...
Page 35: ...1 24 ...
Page 36: ...1 25 ...
Page 37: ...1 26 ...
Page 38: ...1 27 1 27 E ...
Page 84: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 61 4 62 USER CONTROL CF 69 ...
Page 88: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 69 4 70 USER CONTROL CF 71 ...