5-46
7. Hi8/standard 8 mm Switching Position Adjustment
(VC-235 board)
If deviated in this case causes switching noise or jitter on the Hi8/
standard 8 mm mode played back screen.
Mode
Playback
Signal
Hi8/standard 8 mm alignment tape:
For tracking adjustment
(WR5-1NP(NTSC))
(WR5-1CP(PAL))
Measurement Point
CH1: Pin
8
of CN1108
(VC RF SWP)
CH2: Pin
5
of CN1108 (PB RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
62, 63
Specified Value
t1=0 ± 10 µsec
Adjusting Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 22, set data: C0, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 2E, and set data: 02.
4)
Set to the playback mode.
5)
Select page: F, address: 62, change the data and minimize “t1”,
and then press the PAUSE button. (Coarse adjustment)
6)
Select page: F, address: 63, change the data and adjust so that
the switching position (t1) becomes the specified value. (Fine
adjustment)
7)
Press the PAUSE button.
8)
Select page: F, address: 22, set data: 80, and press the PAUSE
button.
9)
Select page: 2, address: 2E, and set data: 00.
10) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-7
CH1
CH2
Enlargement
t1=0
±
10
µ
sec
CH1
CH2
8. CAP FG Duty Adjustment (VC-235 board)
Improve the capstan servo characteristic. If it is not correct. jitters
will increase.
Mode
Playback
Signal
Hi8/standard 8 mm alignment tape:
For checking operation
(WR5-5NSP(NTSC))
(WR5-5CSP(PAL))
Measurement Point
Pin
qg
of CN1108 (CAP FG)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
64
Specified value
Duty=50 ± 1%
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 2E, and set data: 02.
3)
Set to the playback mode.
4)
Select page: 6, address: 01, set data: 81, and press the PAUSE
button of the adjustment remote commander. (to start up
automatic CAP FG offset adjustment.)
5)
Select page: 6, address: 02, and check that the data is “01”.
6)
Check that Duty of CAP FG signal satisfies the specified value.
If not, select page: 6, address: 01, set data: 00, and press the
PAUSE button, and then, repeat steps 4) to 6).
7)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
8)
Select page: 2, address: 2E, and set data: 00.
9)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-8
A
B
Duty = A/B
×
100 [%]
Center of movement
Summary of Contents for DCR-TRV120P
Page 13: ...1 2 ...
Page 14: ...1 3 ...
Page 15: ...1 4 ...
Page 16: ...1 5 ...
Page 17: ...1 6 ...
Page 18: ...1 7 ...
Page 19: ...1 8 ...
Page 20: ...1 9 ...
Page 21: ...1 10 ...
Page 22: ...1 11 ...
Page 23: ...1 12 ...
Page 24: ...1 13 ...
Page 25: ...1 14 ...
Page 26: ...1 15 ...
Page 27: ...1 16 ...
Page 28: ...1 17 ...
Page 29: ...1 18 ...
Page 30: ...1 19 ...
Page 31: ...1 20 ...
Page 32: ...1 21 ...
Page 33: ...1 22 ...
Page 34: ...1 23 ...
Page 35: ...1 24 ...
Page 36: ...1 25 ...
Page 37: ...1 26 ...
Page 38: ...1 27 1 27 E ...
Page 84: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 61 4 62 USER CONTROL CF 69 ...
Page 88: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 69 4 70 USER CONTROL CF 71 ...