4. S VIDEO OUT Chroma Level Adjustment
(VC-235 board)
Mode
VTR stop
Subject
Arbitrary
Measurement Point
Chroma signal terminal of S VIDEO
jack (75
Ω
terminated)
External trigger: Y signal terminal of
S VIDEO jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Specified Value
Cr level: A=714 ± 14 mV (NTSC)
A=700 ± 14 mV (PAL)
Cb level: B=714 ± 14 mV (NTSC)
B=700 ± 14 mV (PAL)
Burst level: C=286 ± 6 mV (NTSC)
C=300 ± 6 mV (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 10, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 0C, set data: 02, and press the PAUSE
button.
4)
Select page: C, address: 26, change the data and set the Cr
signal level (A) to the specified value.
5)
Press the PAUSE button.
6)
Select page: C, address: 27, change the data and set the Cb
signal level (B) to the specified value.
7)
Press the PAUSE button.
8)
Check that the burst signal level (C) is satisfied the specified
value.
9)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button.
10) Select page: D, address: 11, set data: 00, and press the PAUSE
button.
11) Select page: 0, address: 01, and set data: 00.
3. S VIDEO OUT Y Level Adjustment (VC-235 board)
Mode
VTR stop
Subject
Arbitrary
Measurement Point
Y signal terminal of S VIDEO jack
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25
Specified Value
A = 1000 ± 20 mV
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 10, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 0C, set data: 02, and press the PAUSE
button.
4)
Select page: C, address: 25, change the data and set the Y signal
level (A) to the specified value.
5)
Press the PAUSE button.
6)
Select page: 3, address: 0C, set data: 00, and press the PAUSE
button.
7)
Select page: D, address: 11, set data: 00, and press the PAUSE
button.
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-11
Fig. 5-3-12
H
A
H
C
A
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
B
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
Summary of Contents for DCR-TRV120P
Page 13: ...1 2 ...
Page 14: ...1 3 ...
Page 15: ...1 4 ...
Page 16: ...1 5 ...
Page 17: ...1 6 ...
Page 18: ...1 7 ...
Page 19: ...1 8 ...
Page 20: ...1 9 ...
Page 21: ...1 10 ...
Page 22: ...1 11 ...
Page 23: ...1 12 ...
Page 24: ...1 13 ...
Page 25: ...1 14 ...
Page 26: ...1 15 ...
Page 27: ...1 16 ...
Page 28: ...1 17 ...
Page 29: ...1 18 ...
Page 30: ...1 19 ...
Page 31: ...1 20 ...
Page 32: ...1 21 ...
Page 33: ...1 22 ...
Page 34: ...1 23 ...
Page 35: ...1 24 ...
Page 36: ...1 25 ...
Page 37: ...1 26 ...
Page 38: ...1 27 1 27 E ...
Page 84: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 61 4 62 USER CONTROL CF 69 ...
Page 88: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 69 4 70 USER CONTROL CF 71 ...