5-29
3. VCO Adjustment (PD-117 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin
8
of CN5502 (XHD OUT)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
A2 (NTSC model)
A2, A3 (PAL model)
Specified Value
f=15734 ± 30 Hz (NTSC model)
f=15625 ± 30 Hz (PAL model)
Note 1:
NTSC model: DCR-TRV120/TRV120P
PAL model: DCR-TRV120E/TRV125E
Adjusting method (NTSC model):
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: A2, change the data and set the VCO
frequency (f) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Adjusting method (PAL model):
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: A2, change the data, and set the VCO
frequency (f) to the specified value.
3)
Press the PAUSE button of adjustment remote commander.
4)
Read the adjustment data of step 2), and this data is named
D
A2
.
5)
Convert D
A2
to decimal notation, and obtain D
A2
’.
(Refer to Table 5-4-1 “Hexdecimal-decimal conversion table”
of “5-4. Service Mode”)
6)
Calculate D
A3
’ using following equations (decimal calculation),
convert it to a hexdecimal number, and obtain D
A3
.
TYPE C model: D
A3
’ = D
A2
’ – 16
TYPE S 123 k model: D
A3
’ = D
A2
’ – 23
Note2:
If D
A3
’ < 0, then D
A2
= “00”
7)
Select page: D, address: A3, set data D
A3
, and then press the
PAUSE button of adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
2. LCD Initial Data Input (2)
Mode
VTR stop
Signal
Arbitrary
Adjustment Page
D
Adjustment Address
A0 to AA, AC to B1
Note:
TYPE S 61 k model: DCR-TRV120/TRV120P
TYPE S 123 k model: DCR-TRV120E: AEP, UK, EE, NE,
RU/TRV125E
TYPE C model: DCR-TRV120E: E, HK, AUS, CN, JE
Adjusting method:
1)
Select page: 0, address:01, and set data: 01.
2)
Select page: D, and input the data in the following table.
Note:
To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjustment remote commander
each time to set the data.
3)
Select page: 0, address:01, and set data: 00.
Data
Address
TYPE S
TYPE C
Remark
61 k
123 k
A0
78
78
78
Fixed data
A1
95
95
95
A2
80
80
80
VCO adj.
A3
70
70
70
VCO adj. (PAL model)
Fixed data (NTSC model)
A4
80
80
80
V-COM adj.
A5
30
30
20
RGB AMP adj.
A6
00
00
00
Fixed data
A7
C0
C0
80
COM AMP adj.
A8
80
80
80
White balance adj.
A9
80
80
80
AA
50
50
30
Contrast adj.
AC
14
33
0A
Fixed data
AD
14
14
0E
AE
9F
9F
9F
AF
1F
1F
1F
B0
FC
FC
FC
B1
FF
FF
FF
Summary of Contents for DCR-TRV120P
Page 13: ...1 2 ...
Page 14: ...1 3 ...
Page 15: ...1 4 ...
Page 16: ...1 5 ...
Page 17: ...1 6 ...
Page 18: ...1 7 ...
Page 19: ...1 8 ...
Page 20: ...1 9 ...
Page 21: ...1 10 ...
Page 22: ...1 11 ...
Page 23: ...1 12 ...
Page 24: ...1 13 ...
Page 25: ...1 14 ...
Page 26: ...1 15 ...
Page 27: ...1 16 ...
Page 28: ...1 17 ...
Page 29: ...1 18 ...
Page 30: ...1 19 ...
Page 31: ...1 20 ...
Page 32: ...1 21 ...
Page 33: ...1 22 ...
Page 34: ...1 23 ...
Page 35: ...1 24 ...
Page 36: ...1 25 ...
Page 37: ...1 26 ...
Page 38: ...1 27 1 27 E ...
Page 84: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 61 4 62 USER CONTROL CF 69 ...